Experimental and computational analysis and testing of wearable hand tremor control orthoses

Hand tremors are among the most prevalent neurodegenerative movement disorders, causing involuntary upper-limb oscillations that significantly impair patients' quality of life. While medications and therapy provide limited relief, wearable tremor suppression devices offer a promising non-invasive alternative. A hand tremor absorber, typically passive or active, is designed to counteract involuntary shaking through mechanical or electronic means. The importance of the proposed design lies in its ability to deliver high-performance, multi-axial tremor suppression without motors, power sources, or restrictive bracing, addressing critical gaps in comfort, wearability, and real-world usability that limit existing solutions. This paper presents the analysis and optimisation of a novel passive, omnidirectional hand tremor absorber that achieves substantial amplitude reduction while preserving natural hand motion. Using a full-scale mannequin arm tremor simulator and MATLAB-based parametric modelling (MathWorks Inc., Natick, MA), key design parameters were optimised across the clinically relevant 3-7 Hz frequency range. Results demonstrate up to 79% unidirectional and 73% omnidirectional tremor suppression. A compact, donut-shaped orthosis integrating dual perpendicular absorbers was developed to effectively dampen complex, multi-directional tremors, achieving ∼75% reduction in severe cases with a total device weight of only 330 g. By combining passive operation, lightweight ergonomics, and multi-axis efficacy, this design offers a practical, patient-centered solution that overcomes the bulk, cost, and invasiveness of current alternatives. Future work will validate these results in human trials to assess real-world impact on functional independence and quality of life.

Authors

Institutions

Publication Details

Journal
Journal of Medical Engineering & Technology
Published
2025-12-12
DOI
https://doi.org/10.1080/03091902.2025.2593410
Primary Topic
Neurological disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and computational analysis and testing of wearable hand tremor control orthoses

Hadi Mohammadi, Manthan Shah, Dylan Goode
Journal of Medical Engineering & Technology
Neurological disorders and treatments
article

Experimental and computational analysis and testing of wearable hand tremor control orthoses

Hadi Mohammadi, Manthan Shah, Dylan Goode
article en

Abstract

Hand tremors are among the most prevalent neurodegenerative movement disorders, causing involuntary upper-limb oscillations that significantly impair patients' quality of life. While medications and therapy provide limited relief, wearable tremor suppression devices offer a promising non-invasive alternative. A hand tremor absorber, typically passive or active, is designed to counteract involuntary shaking through mechanical or electronic means. The importance of the proposed design lies in its ability to deliver high-performance, multi-axial tremor suppression without motors, power sources, or restrictive bracing, addressing critical gaps in comfort, wearability, and real-world usability that limit existing solutions. This paper presents the analysis and optimisation of a novel passive, omnidirectional hand tremor absorber that achieves substantial amplitude reduction while preserving natural hand motion. Using a full-scale mannequin arm tremor simulator and MATLAB-based parametric modelling (MathWorks Inc., Natick, MA), key design parameters were optimised across the clinically relevant 3-7 Hz frequency range. Results demonstrate up to 79% unidirectional and 73% omnidirectional tremor suppression. A compact, donut-shaped orthosis integrating dual perpendicular absorbers was developed to effectively dampen complex, multi-directional tremors, achieving ∼75% reduction in severe cases with a total device weight of only 330 g. By combining passive operation, lightweight ergonomics, and multi-axis efficacy, this design offers a practical, patient-centered solution that overcomes the bulk, cost, and invasiveness of current alternatives. Future work will validate these results in human trials to assess real-world impact on functional independence and quality of life.

Journal of Medical Engineering & Technology
Valve (United States) (US)
Openalex Percentile: Top 45%
Neurological disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.