Load Management After Gluteal Tendon Repair: A Controlled Laboratory Study

Tendon lesions of the gluteus medius muscle require surgical repair if conservative treatment fails. Postoperatively, the success of the therapy is influenced by the loading conditions during follow-up treatment. Excessive loading of the hip joint during walking after surgery - and consequently, potential overload of the repaired gluteal tendon - could jeopardize the success of the therapy. In this controlled laboratory study, six subjects performed an instrumented 3D gait analysis using optoelectronic motion capture under three different loading conditions: full weight-bearing, partial weight-bearing, and full unloading with crutches. Gait data were used in silico in an inverse dynamics multi-body simulation to calculate tendon loading. Peak loads occurred on the gluteal tendons and the hip joint during the stance phase. The force on the gluteus medius tendon during full weight-bearing amounted to F<sub>me</sub> = 12.0 ( ± 1.5) N/kg BW, while the force on the gluteus minimus tendon was F<sub>mi</sub> = 5.0 ( ± 1.6) N/kg BW. Partial weight-bearing reduced these loads by ≈ 68%, whereas full unloading led to a ≈ 88% reduction compared to full weight-bearing. In the hip joint, the average maximum load during full weight-bearing reached F<sub>H</sub> = 39.8 ( ± 6.7) N/kg BW. To prevent muscle atrophy after gluteal tendon repair, the highest possible load should be applied without compromising suture integrity. Full unloading should be implemented if the tendon and/or bone integrity is compromised and suture stability is reduced. However, if stability is sufficient, partial weight-bearing is recommended.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2025-12-13
DOI
https://doi.org/10.1002/jor.70107
Primary Topic
Tendon Structure and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Load Management After Gluteal Tendon Repair: A Controlled Laboratory Study

Stefan Budde, Michaël Schwarze, Alexander Derksen, Christof Hurschler et al.
Journal of Orthopaedic Research®
Tendon Structure and Treatment
article

Load Management After Gluteal Tendon Repair: A Controlled Laboratory Study

Stefan Budde, Michaël Schwarze, Alexander Derksen, Christof Hurschler, Eike Jakubowitz, Corinna Wicke, Henning Windhagen
article en

Abstract

Tendon lesions of the gluteus medius muscle require surgical repair if conservative treatment fails. Postoperatively, the success of the therapy is influenced by the loading conditions during follow-up treatment. Excessive loading of the hip joint during walking after surgery - and consequently, potential overload of the repaired gluteal tendon - could jeopardize the success of the therapy. In this controlled laboratory study, six subjects performed an instrumented 3D gait analysis using optoelectronic motion capture under three different loading conditions: full weight-bearing, partial weight-bearing, and full unloading with crutches. Gait data were used in silico in an inverse dynamics multi-body simulation to calculate tendon loading. Peak loads occurred on the gluteal tendons and the hip joint during the stance phase. The force on the gluteus medius tendon during full weight-bearing amounted to F<sub>me</sub> = 12.0 ( ± 1.5) N/kg BW, while the force on the gluteus minimus tendon was F<sub>mi</sub> = 5.0 ( ± 1.6) N/kg BW. Partial weight-bearing reduced these loads by ≈ 68%, whereas full unloading led to a ≈ 88% reduction compared to full weight-bearing. In the hip joint, the average maximum load during full weight-bearing reached F<sub>H</sub> = 39.8 ( ± 6.7) N/kg BW. To prevent muscle atrophy after gluteal tendon repair, the highest possible load should be applied without compromising suture integrity. Full unloading should be implemented if the tendon and/or bone integrity is compromised and suture stability is reduced. However, if stability is sufficient, partial weight-bearing is recommended.

Journal of Orthopaedic Research®Vol. 44(1)
Medizinische Hochschule Hannover (DE), Hochschule Bremerhaven (DE), Evangelisches Krankenhaus Bielefeld (DE), Diakonie Deutschland (DE)
Medizinischen Hochschule Hannover
Openalex Percentile: Top 50%
Tendon Structure and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.