Image quality with reduced radiation dose and contrast medium of cardiac computed tomography in infants with congenital heart disease using 70 KVP and DEEP-learning reconstruction with 256-detector CT

This study compared radiation dose, vascular enhancement, and contrast-to-noise ratio (CNR) of 256-multidetector row computed tomography (MDCT) at 70 kVp with deep-learning reconstruction (DLR) to 64-MDCT at 80 kVp with ASiR of cardiac CT angiography (CCTA) in infants with congenital heart disease. The contrast medium (CM) was 266 mg/kg for the 256-MDCT group and 600 mg/kg for the 64-MDCT group. In the 256- and 64-MDCT groups, the median values were 0.45 and 0.75 mGy for adjusted volume CT dose index (P < .05) and 4.98 and 8.00 mGy-cm for dose length product (P < .05). Despite a 49% CM reduction in the 256-MDCT group, vascular enhancement and CNR showed no significant differences (P > .05). The 256-MDCT at 70 kVp with DLR can maintain vascular CT enhancement and CNR while reducing CM by 49% and radiation dose by 41% in infant CCTA, compared with 64-MDCT at 80 kVp with ASiR.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-11-27
DOI
https://doi.org/10.1093/rpd/ncaf152
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Image quality with reduced radiation dose and contrast medium of cardiac computed tomography in infants with congenital heart disease using 70 KVP and DEEP-learning reconstruction with 256-detector CT

Tomoyasu Sato, Takanori Masuda, Takayuki Yoshiura, Takayuki Oku et al.
Radiation Protection Dosimetry
Radiation Dose and Imaging
article

Image quality with reduced radiation dose and contrast medium of cardiac computed tomography in infants with congenital heart disease using 70 KVP and DEEP-learning reconstruction with 256-detector CT

Tomoyasu Sato, Takanori Masuda, Takayuki Yoshiura, Takayuki Oku, Yoshinori Funama, Yukari Kikuhara, Yuma Yamamoto, Yukie Kobayashi, Tomohiro Kimura
article en

Abstract

This study compared radiation dose, vascular enhancement, and contrast-to-noise ratio (CNR) of 256-multidetector row computed tomography (MDCT) at 70 kVp with deep-learning reconstruction (DLR) to 64-MDCT at 80 kVp with ASiR of cardiac CT angiography (CCTA) in infants with congenital heart disease. The contrast medium (CM) was 266 mg/kg for the 256-MDCT group and 600 mg/kg for the 64-MDCT group. In the 256- and 64-MDCT groups, the median values were 0.45 and 0.75 mGy for adjusted volume CT dose index (P < .05) and 4.98 and 8.00 mGy-cm for dose length product (P < .05). Despite a 49% CM reduction in the 256-MDCT group, vascular enhancement and CNR showed no significant differences (P > .05). The 256-MDCT at 70 kVp with DLR can maintain vascular CT enhancement and CNR while reducing CM by 49% and radiation dose by 41% in infant CCTA, compared with 64-MDCT at 80 kVp with ASiR.

Radiation Protection DosimetryVol. 202(1)
Kumamoto Health Science University (JP), Kajima Corporation (Japan) (JP), Kawasaki University of Medical Welfare (JP), Kumamoto University (JP)
Openalex Percentile: Top 45%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.