High-resolution field deployable instrument line shape calibrated-laser heterodyne radiometer for accurate atmospheric methane (CH4) detection

• Development of a high-resolution LHR based on near-infrared laser heterodyne spectroscopy. • Implementation of on-site calibration of ILS for LHR. • The ILS-calibrated LHR is field deployable and more accurate. • The ILS-calibrated LHR performance was verified by remote sensing of atmospheric methane (CH 4 ). The performance of a near-infrared (NIR) high-resolution field deployable instrument line shape (ILS) calibrated-laser heterodyne radiometer (LHR) for accurate measurement of atmospheric CH 4 column abundance is demonstrated. The ILS-calibrated LHR employs a distributed feedback (DFB) laser centered at 1653 nm to extract the CH 4 absorption spectrum information in the atmospheric column from solar radiation. Based on the measured spectra and regularization deconvolution algorithm, the ILS of the LHR is accurately determined. Validation of the retrieved ILS is performed using low-pressure CH 4 gas cell, and the accuracy is improved by 97 % compared to conventional ILS. Compared to traditional LHRs, the ILS-calibrated LHR leads to a 30 % reduction in residuals near the wings of the absorption lines and a 200 % reduction at the peak positions, resulting in a 10 % enhancement in the accuracy of the column abundance determination. The reported field deployable ILS-calibrated LHR provides valuable insights for the accurate measurement of greenhouse gases in Earth’s atmosphere.

Authors

Institutions

Publication Details

Journal
Optics & Laser Technology
Published
2025-12-13
DOI
https://doi.org/10.1016/j.optlastec.2025.114424
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-resolution field deployable instrument line shape calibrated-laser heterodyne radiometer for accurate atmospheric methane (CH4) detection

X. B. Gao, Guishi Wang, Jun Li, Tu Tan et al.
Optics & Laser Technology
Spectroscopy and Laser Applications
article

High-resolution field deployable instrument line shape calibrated-laser heterodyne radiometer for accurate atmospheric methane (CH4) detection

X. B. Gao, Guishi Wang, Jun Li, Tu Tan, Zhengyue Xue, Fengjiao Shen, Kun Liu, Yu Wang, Jingjing Wang, Yun Zhang
article en

Abstract

• Development of a high-resolution LHR based on near-infrared laser heterodyne spectroscopy. • Implementation of on-site calibration of ILS for LHR. • The ILS-calibrated LHR is field deployable and more accurate. • The ILS-calibrated LHR performance was verified by remote sensing of atmospheric methane (CH 4 ). The performance of a near-infrared (NIR) high-resolution field deployable instrument line shape (ILS) calibrated-laser heterodyne radiometer (LHR) for accurate measurement of atmospheric CH 4 column abundance is demonstrated. The ILS-calibrated LHR employs a distributed feedback (DFB) laser centered at 1653 nm to extract the CH 4 absorption spectrum information in the atmospheric column from solar radiation. Based on the measured spectra and regularization deconvolution algorithm, the ILS of the LHR is accurately determined. Validation of the retrieved ILS is performed using low-pressure CH 4 gas cell, and the accuracy is improved by 97 % compared to conventional ILS. Compared to traditional LHRs, the ILS-calibrated LHR leads to a 30 % reduction in residuals near the wings of the absorption lines and a 200 % reduction at the peak positions, resulting in a 10 % enhancement in the accuracy of the column abundance determination. The reported field deployable ILS-calibrated LHR provides valuable insights for the accurate measurement of greenhouse gases in Earth’s atmosphere.

Optics & Laser TechnologyVol. 194
University of Science and Technology of China (CN), University of Shanghai for Science and Technology (CN), Chinese Academy of Sciences (CN), Hefei Institutes of Physical Science (CN), Hefei University (CN), Anhui Business College (CN), Anhui Institute of Optics and Fine Mechanics (CN)
Openalex Percentile: Top 64%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.