Power quality enhancement using fractional order type-2 fuzzy SHAF optimized with hPSOFA algorithm

Reactive Power & Harmonic compensation (RPHC) represents a crucial area of investigation within the domains of power engineering. While passive filters have traditionally been favored for mitigating harmonics, their size becomes impractical when addressing multiple harmonics. In contrast, active power filters offer enhanced performance and address the limitations of passive filters, albeit at a higher cost. This study introduces a Shunt Hybrid Active Filter (SHAF) designed for RPHC. In our approach, the Kalman Filter (KF) is utilized for estimation of reference current per-unit (PU) quantity and the current reference crest value, which are derived from a Type-2 Fuzzy Fractional Order PID Controller (T2FFOPIDC). The optimal parameters for the T2FFOPIDC are determined using an innovative hybrid Particle Swarm Optimization (PSO) Firefly Algorithm (hPSOFA), with a focus on minimizing the ITAE. The suggested system is validated, taking balanced as well as unbalanced nonlinear loads, and the outcomes are contrasted with those obtained from an SHAF system based on the Type-1 Fuzzy Fractional Order PID Controller (T1FFOPIDC), which is also optimized using hPSOFA. The compensation strategy employed in the SHAF differs from the conventional (id-iq) or (p-q) techniques, as it necessitates the current from the source side. Various performance metrics, including Reactive Power (Q), THD, and PFS, are assessed to evaluate the effectiveness of the proposed controller. Case studies reveal that the hPSOFA-T2FFOPIDC-based SHAF demonstrates superior RPHC compared to the hPSOFA-T1FFOPIDC-based SHAF across various operational scenarios. Furthermore, the performance of the proposed hPSOFA-T2FFOPIDC-SHAF has been experimentally validated using dSPACE.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-13
DOI
https://doi.org/10.1038/s41598-025-32199-0
Citations
1
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power quality enhancement using fractional order type-2 fuzzy SHAF optimized with hPSOFA algorithm

Jeevan Jyoti Mahakud, Amaresh Gantayet, Akshaya Kumar Patra, Alok Kumar Mishra et al.
1 citations
Scientific Reports
Power Quality and Harmonics
0.73
article

Power quality enhancement using fractional order type-2 fuzzy SHAF optimized with hPSOFA algorithm

Jeevan Jyoti Mahakud, Amaresh Gantayet, Akshaya Kumar Patra, Alok Kumar Mishra, Sushanta Kumar Kamilla, Satish Choudhury, Lalit Mohan Satapathy
article en
1 citations

Abstract

Reactive Power & Harmonic compensation (RPHC) represents a crucial area of investigation within the domains of power engineering. While passive filters have traditionally been favored for mitigating harmonics, their size becomes impractical when addressing multiple harmonics. In contrast, active power filters offer enhanced performance and address the limitations of passive filters, albeit at a higher cost. This study introduces a Shunt Hybrid Active Filter (SHAF) designed for RPHC. In our approach, the Kalman Filter (KF) is utilized for estimation of reference current per-unit (PU) quantity and the current reference crest value, which are derived from a Type-2 Fuzzy Fractional Order PID Controller (T2FFOPIDC). The optimal parameters for the T2FFOPIDC are determined using an innovative hybrid Particle Swarm Optimization (PSO) Firefly Algorithm (hPSOFA), with a focus on minimizing the ITAE. The suggested system is validated, taking balanced as well as unbalanced nonlinear loads, and the outcomes are contrasted with those obtained from an SHAF system based on the Type-1 Fuzzy Fractional Order PID Controller (T1FFOPIDC), which is also optimized using hPSOFA. The compensation strategy employed in the SHAF differs from the conventional (id-iq) or (p-q) techniques, as it necessitates the current from the source side. Various performance metrics, including Reactive Power (Q), THD, and PFS, are assessed to evaluate the effectiveness of the proposed controller. Case studies reveal that the hPSOFA-T2FFOPIDC-based SHAF demonstrates superior RPHC compared to the hPSOFA-T1FFOPIDC-based SHAF across various operational scenarios. Furthermore, the performance of the proposed hPSOFA-T2FFOPIDC-SHAF has been experimentally validated using dSPACE.

Scientific ReportsVol. 16(1)
Siksha O Anusandhan University (IN)
Openalex Percentile: Top 21%
Power Quality and Harmonics
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.