Design–performance relationships in Ti-6Al-4V lattice metamaterials: in-vivo osseointegration and ex-vivo biomechanical pull-out assessment

• Large-animal in-vivo study of gyroid vs stochastic Ti-6Al-4 V lattices. • Gyroid 0.2 relative density showed the highest fixation (∼2.0 kN), displacement (∼5 mm), and energy (>9 J). • Increasing density to 0.3 reduced bone ingrowth, showing a porosity–strength trade-off. • Stochastic lattices matched strength but showed higher variability in fixation outcomes. • Surface etching improved gyroid 0.2 fixation but not in dense stochastic lattices. This study investigated the influence of lattice topology, relative density, and surface condition on the osseointegration and biomechanical fixation of porous Ti-6Al-4 V implants in a large-animal model. Eight horses received cylindrical gyroid or stochastic scaffolds (0.2 and 0.3 relative density; as-built and chemically etched) bilaterally in the tuber coxae for six months. Postmortem analyses included radiography, SEM, histology, and axial pull-out testing. Gyroid lattices at a relative density of 0.2 achieved the most favorable balance of fixation strength (∼2.0 kN), displacement (∼5 mm), deformation energy (>9 J), and bone ingrowth, indicating progressive rather than abrupt failure at the interface. Increasing relative density to 0.3 enhanced stiffness but reduced bone infiltration and fixation, reflecting a porosity–strength trade-off. Stochastic lattices reached similar mean fixation strength but showed higher variability due to heterogeneous bone contact. Chemical etching enhanced displacement and energy absorption in gyroid 0.2 lattices but was unable to compensate for poor infiltration in high-density stochastic scaffolds. Overall, lattice topology and relative density governed fixation outcomes more strongly than surface state, underscoring the translational potential of TPMS-based titanium lattices for future load-bearing orthopedic applications.

Authors

Publication Details

Journal
Materials & Design
Published
2025-12-13
DOI
https://doi.org/10.1016/j.matdes.2025.115327
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design–performance relationships in Ti-6Al-4V lattice metamaterials: in-vivo osseointegration and ex-vivo biomechanical pull-out assessment

Mylène de Ruijter, Harold Brommer, Antti Järvenpää, Jos Malda et al.
Materials & Design
Bone Tissue Engineering Materials
article

Design–performance relationships in Ti-6Al-4V lattice metamaterials: in-vivo osseointegration and ex-vivo biomechanical pull-out assessment

Mylène de Ruijter, Harold Brommer, Antti Järvenpää, Jos Malda, Teodolíto Guillén-Girón, Miguel Araya, Rafael Vindas-Bolaños, Roberto J. Estrada, Eva Stronkman
article en

Abstract

• Large-animal in-vivo study of gyroid vs stochastic Ti-6Al-4 V lattices. • Gyroid 0.2 relative density showed the highest fixation (∼2.0 kN), displacement (∼5 mm), and energy (>9 J). • Increasing density to 0.3 reduced bone ingrowth, showing a porosity–strength trade-off. • Stochastic lattices matched strength but showed higher variability in fixation outcomes. • Surface etching improved gyroid 0.2 fixation but not in dense stochastic lattices. This study investigated the influence of lattice topology, relative density, and surface condition on the osseointegration and biomechanical fixation of porous Ti-6Al-4 V implants in a large-animal model. Eight horses received cylindrical gyroid or stochastic scaffolds (0.2 and 0.3 relative density; as-built and chemically etched) bilaterally in the tuber coxae for six months. Postmortem analyses included radiography, SEM, histology, and axial pull-out testing. Gyroid lattices at a relative density of 0.2 achieved the most favorable balance of fixation strength (∼2.0 kN), displacement (∼5 mm), deformation energy (>9 J), and bone ingrowth, indicating progressive rather than abrupt failure at the interface. Increasing relative density to 0.3 enhanced stiffness but reduced bone infiltration and fixation, reflecting a porosity–strength trade-off. Stochastic lattices reached similar mean fixation strength but showed higher variability due to heterogeneous bone contact. Chemical etching enhanced displacement and energy absorption in gyroid 0.2 lattices but was unable to compensate for poor infiltration in high-density stochastic scaffolds. Overall, lattice topology and relative density governed fixation outcomes more strongly than surface state, underscoring the translational potential of TPMS-based titanium lattices for future load-bearing orthopedic applications.

Materials & DesignVol. 261
Openalex Percentile: Top 61%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.