Contrast‐Enhanced Ultrasound (CEUS) Reveals Perfusion of Human Bone in Acute Fracture Healing: A Pilot Study

Bone fractures are common injuries with reported non-union rates of up to 9%. Current treatments for non-union include surgery with complication rates of up to 17% and significant costs. Microbubbles are used clinically in ultrasonography as contrast agents and have been shown to deliver therapeutics to desired locations by noninvasive stimulation of cavitation using extracorporeal ultrasound in preclinical studies. Contrast enhanced ultrasound (CEUS) has been used to determine the cause of established fracture non-unions, though this is not in widespread use clinically. This pilot study aimed to test the hypothesis that peripherally injected microbubbles are detectable in acute fracture sites. Adult patients (18-75 yrs) with acute humeral shaft fractures were recruited to undergo CEUS within 28 days of injury. They underwent peripheral injection of SonoVue microbubbles with ultrasound imaging. B-mode and contrast-mode videos were collected and time-intensity curve analysis was used to assess for the presence of microbubbles at the fracture site. Ten patients were recruited, 8 underwent humeral shaft fracture scans with 7 analysed. All fracture sites demonstrated increased contrast signal following injection. The wash-in volume of microbubbles was greater than the wash-out volume in all cases, with a mean difference of 1.4 × 10⁻⁵ (± 1.7 × 10⁻⁵) (p = 0.015 Wilcoxon Test). There was a trend toward decreasing PI and TtP with fracture age, though not statistically significant (R² = 0.44, p = 0.1; R² = 0.24, p = 0.26, respectively). This pilot study demonstrates that commercially available microbubbles perfuse acute fractures in ultrasonographically detectable quantities using commercially available equipment.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2025-12-13
DOI
https://doi.org/10.1002/jor.70100
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contrast‐Enhanced Ultrasound (CEUS) Reveals Perfusion of Human Bone in Acute Fracture Healing: A Pilot Study

Rachel Schranz, Dario Carugo, Amy Gerrish, Nicholas D. Evans et al.
Journal of Orthopaedic Research®
Ultrasound and Hyperthermia Applications
article

Contrast‐Enhanced Ultrasound (CEUS) Reveals Perfusion of Human Bone in Acute Fracture Healing: A Pilot Study

Rachel Schranz, Dario Carugo, Amy Gerrish, Nicholas D. Evans, David Warwick, Kirk Wallace, Martin J. Thomas, Eleanor Stride, S. Tilley, Jane A. Hurst, Dan Cadoux-Hudson
article en

Abstract

Bone fractures are common injuries with reported non-union rates of up to 9%. Current treatments for non-union include surgery with complication rates of up to 17% and significant costs. Microbubbles are used clinically in ultrasonography as contrast agents and have been shown to deliver therapeutics to desired locations by noninvasive stimulation of cavitation using extracorporeal ultrasound in preclinical studies. Contrast enhanced ultrasound (CEUS) has been used to determine the cause of established fracture non-unions, though this is not in widespread use clinically. This pilot study aimed to test the hypothesis that peripherally injected microbubbles are detectable in acute fracture sites. Adult patients (18-75 yrs) with acute humeral shaft fractures were recruited to undergo CEUS within 28 days of injury. They underwent peripheral injection of SonoVue microbubbles with ultrasound imaging. B-mode and contrast-mode videos were collected and time-intensity curve analysis was used to assess for the presence of microbubbles at the fracture site. Ten patients were recruited, 8 underwent humeral shaft fracture scans with 7 analysed. All fracture sites demonstrated increased contrast signal following injection. The wash-in volume of microbubbles was greater than the wash-out volume in all cases, with a mean difference of 1.4 × 10⁻⁵ (± 1.7 × 10⁻⁵) (p = 0.015 Wilcoxon Test). There was a trend toward decreasing PI and TtP with fracture age, though not statistically significant (R² = 0.44, p = 0.1; R² = 0.24, p = 0.26, respectively). This pilot study demonstrates that commercially available microbubbles perfuse acute fractures in ultrasonographically detectable quantities using commercially available equipment.

Journal of Orthopaedic Research®Vol. 44(1)
Southampton Hospital (US), Southampton General Hospital (GB), University Hospital Southampton NHS Foundation Trust (GB), University of Oxford (GB), NIHR Southampton Biomedical Research Centre (GB), GE Global Research (United States) (US), Science Oxford (GB), University of Southampton (GB)
Engineering and Physical Sciences Research Council, EPSRC Centre for Doctoral Training in Medical Imaging
Openalex Percentile: Top 61%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.