Integrating aperture shape controller and machine learning prediction to improve gamma passing rates in lattice radiotherapy

<i>Objective.</i>This study proposes a workflow integrating the aperture shape controller (ASC) in the Varian Eclipse system with a machine learning-based verification prediction model to improve gamma passing rates (GPRs) of LATTICE Radiotherapy (LRT) plans and reduce repeated verifications.<i>Approach.</i>LRT plans were generated on CT images from 20 patients (five each with head and neck, thoracic, abdominal, and bone metastases) using a Varian Halcyon v3.0. Twenty IMRT-based Non_ASC_LRT plans (nine fields each, 180 fields total) were created and re-optimized with ASC set to 'Very High,' producing ASC_LRT plans. All plans underwent portal dosimetry. Plan complexity features were extracted from Digital Imaging and Communications in Medicine files, and dosimetric parameters from DVHs. An eXtreme gradient boosting (XGBoost) classifier was trained 5 times with cross-validation on a balanced dataset of 196 fields generated by under-sampling and SMOTE, and subsequently applied to failed fields in Non_ASC_LRT plans to evaluate its potential guidance for ASC application.<i>Main results.</i>ASC optimization improved GPR in fields with baseline values <98% (mean increase 1.95%,<i>p</i>< 0.05), while overall GPR showed no significant change. Dosimetric parameters (<i>D</i><sub>max</sub>,<i>D</i><sub>mean</sub>_target,<i>D</i><sub>mean</sub>_vertex, and valley-to-peak dose ratio (VPDR)) were not significantly affected, though VPDR showed a slight overall increase. Over five training rounds, the XGBoost model achieved an average accuracy of 94.38%, sensitivity of 94.60%, specificity of 94.13%, precision of 93.57%, and an<i>F</i>1-score of 93.98%. All six failed fields in Non_ASC_LRT plans were correctly identified, and five passed verification after ASC optimization, reducing re-planning.<i>Significance.</i>Combining ASC with a prediction model effectively balances dosimetric quality and deliverability in LRT, enhances GPR in low-performing fields, and reduces verification workload, thereby improving clinical efficiency.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-12-11
DOI
https://doi.org/10.1088/1361-6560/ae2bba
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrating aperture shape controller and machine learning prediction to improve gamma passing rates in lattice radiotherapy

Minghe Lv, E Xiangyu, Ruping Zhao, Jingping Yu et al.
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
article

Integrating aperture shape controller and machine learning prediction to improve gamma passing rates in lattice radiotherapy

Minghe Lv, E Xiangyu, Ruping Zhao, Jingping Yu, Su Zeng, Yue Feng, Hongwei Zeng
article en

Abstract

<i>Objective.</i>This study proposes a workflow integrating the aperture shape controller (ASC) in the Varian Eclipse system with a machine learning-based verification prediction model to improve gamma passing rates (GPRs) of LATTICE Radiotherapy (LRT) plans and reduce repeated verifications.<i>Approach.</i>LRT plans were generated on CT images from 20 patients (five each with head and neck, thoracic, abdominal, and bone metastases) using a Varian Halcyon v3.0. Twenty IMRT-based Non_ASC_LRT plans (nine fields each, 180 fields total) were created and re-optimized with ASC set to 'Very High,' producing ASC_LRT plans. All plans underwent portal dosimetry. Plan complexity features were extracted from Digital Imaging and Communications in Medicine files, and dosimetric parameters from DVHs. An eXtreme gradient boosting (XGBoost) classifier was trained 5 times with cross-validation on a balanced dataset of 196 fields generated by under-sampling and SMOTE, and subsequently applied to failed fields in Non_ASC_LRT plans to evaluate its potential guidance for ASC application.<i>Main results.</i>ASC optimization improved GPR in fields with baseline values <98% (mean increase 1.95%,<i>p</i>< 0.05), while overall GPR showed no significant change. Dosimetric parameters (<i>D</i><sub>max</sub>,<i>D</i><sub>mean</sub>_target,<i>D</i><sub>mean</sub>_vertex, and valley-to-peak dose ratio (VPDR)) were not significantly affected, though VPDR showed a slight overall increase. Over five training rounds, the XGBoost model achieved an average accuracy of 94.38%, sensitivity of 94.60%, specificity of 94.13%, precision of 93.57%, and an<i>F</i>1-score of 93.98%. All six failed fields in Non_ASC_LRT plans were correctly identified, and five passed verification after ASC optimization, reducing re-planning.<i>Significance.</i>Combining ASC with a prediction model effectively balances dosimetric quality and deliverability in LRT, enhances GPR in low-performing fields, and reduces verification workload, thereby improving clinical efficiency.

Physics in Medicine and BiologyVol. 71(1)
Shanghai University of Traditional Chinese Medicine (CN), Shuguang Hospital (CN)
Openalex Percentile: Top 52%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.