Performance Evaluation of an Urban Wastewater Treatment Plant (WWTP): Statistical and Comparative Approach to Estimate Water Quality and Pollution Indices, a Case Study of Maghnia WWTP, Algeria

Abstract Algeria faces severe water stress, marked by a decrease in water availability per inhabitant from 1,500 m 3 /year in 1962 to 430 m 3 in 2020, with a projection of 300 m 3 by 2050. In this context, optimizing wastewater treatment plants (WWTPs) becomes essential to reduce the water deficit. This study evaluates the performance of the urban wastewater treatment plant of Maghnia (Northwestern Algeria) by carrying out a statistical analysis of physicochemical parameters and comparing the Weighted Arithmetic Water Quality Index (WAWQI) and Water Pollution Index (WPI) based on data collected between January 7, 2020, and March 22, 2021. Reliable detection of outliers was achieved through the combined application of Grubbs and Tukey tests, while data normality was verified by Shapiro–Wilk, Anderson–Darling, and the P-P plot, thus strengthening analytical robustness and minimizing bias. The results show stability of physical parameters (temperature and pH) and moderate variability of chemical parameters, including chemical oxygen demand (COD), total suspended solids (TSS), and biochemical oxygen demand (BOD₅), at the plant inlet. However, notable exceedances of standards at the outlet were observed, notably for ammonium (7.92 mg/l, standard limit: 5 mg/l) and phosphates (10.01 mg/l, standard limit: 2 mg/l), indicating deficiencies in biological treatment despite high organic matter removal efficiency. Bland–Altman analysis confirms the complementarity of the WAWQI and WPI indices, highlighting low quality of treated water and chronic system overload. These results underscore the need for targeted process optimization, particularly for nutrient removal, to ensure safe reuse of treated wastewater.

Authors

Institutions

Publication Details

Journal
Water Air & Soil Pollution
Published
2025-12-13
DOI
https://doi.org/10.1007/s11270-025-08800-7
Citations
2
Primary Topic
Water Quality and Pollution Assessment
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation of an Urban Wastewater Treatment Plant (WWTP): Statistical and Comparative Approach to Estimate Water Quality and Pollution Indices, a Case Study of Maghnia WWTP, Algeria

Madani Bessedik, Abderrahim Badraoui, Chérifa Abdelbaki, Afaf Amara-Rekkab et al.
2 citations
Water Air & Soil Pollution
Water Quality and Pollution Assessment
1.63
article

Performance Evaluation of an Urban Wastewater Treatment Plant (WWTP): Statistical and Comparative Approach to Estimate Water Quality and Pollution Indices, a Case Study of Maghnia WWTP, Algeria

Madani Bessedik, Abderrahim Badraoui, Chérifa Abdelbaki, Afaf Amara-Rekkab, Navneet Kumar, Halima Belarbi
article en
2 citations

Abstract

Abstract Algeria faces severe water stress, marked by a decrease in water availability per inhabitant from 1,500 m 3 /year in 1962 to 430 m 3 in 2020, with a projection of 300 m 3 by 2050. In this context, optimizing wastewater treatment plants (WWTPs) becomes essential to reduce the water deficit. This study evaluates the performance of the urban wastewater treatment plant of Maghnia (Northwestern Algeria) by carrying out a statistical analysis of physicochemical parameters and comparing the Weighted Arithmetic Water Quality Index (WAWQI) and Water Pollution Index (WPI) based on data collected between January 7, 2020, and March 22, 2021. Reliable detection of outliers was achieved through the combined application of Grubbs and Tukey tests, while data normality was verified by Shapiro–Wilk, Anderson–Darling, and the P-P plot, thus strengthening analytical robustness and minimizing bias. The results show stability of physical parameters (temperature and pH) and moderate variability of chemical parameters, including chemical oxygen demand (COD), total suspended solids (TSS), and biochemical oxygen demand (BOD₅), at the plant inlet. However, notable exceedances of standards at the outlet were observed, notably for ammonium (7.92 mg/l, standard limit: 5 mg/l) and phosphates (10.01 mg/l, standard limit: 2 mg/l), indicating deficiencies in biological treatment despite high organic matter removal efficiency. Bland–Altman analysis confirms the complementarity of the WAWQI and WPI indices, highlighting low quality of treated water and chronic system overload. These results underscore the need for targeted process optimization, particularly for nutrient removal, to ensure safe reuse of treated wastewater.

Water Air & Soil PollutionVol. 237(4)
Magadh University (IN), University of Bonn (DE), University of Abou Bekr Belkaïd (DZ), École Supérieure en Sciences Appliquées de Tlemcen (DZ), United Nations University (DE)
Openalex Percentile: Top 14%
Water Quality and Pollution Assessment
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.