Optimized Asymmetrical Fuzzy‐2DOFTIDF Controller for LFC of Three‐Area Multi‐Sources Interconnected Power System Along With HAE‐FC and UPFC Using a New SOA Algorithm

ABSTRACT The increasing complexity and scale of modern power systems, combined with fluctuations in demand, modeling uncertainties, evolving network configurations, and time‐varying characteristics, make load frequency control (LFC) increasingly challenging. Large frequency deviations can disrupt electric clock synchronization, alter AC motor speeds, affect magnetizing currents in transformers and induction motors, and impair the coordinated operation of systems. Conventional control methods often fail to effectively manage these uncertainties. This study evaluates LFC performance in a multi‐area, multi‐source interconnected power system using a novel Asymmetrical‐Fuzzy‐based Two‐Degree‐of‐freedom Tilt‐Integral‐Derivative Controller with Low‐Pass‐Filter (AF‐2DOF‐TIDF) as a secondary control mechanism. The system comprises three unequal areas that integrate hybrid‐thermal and hydropower plants, representing real‐world asymmetries in capacity, inertia, and interconnections. The dynamic influence of Hydrogen‐Aqua‐Electrolyzer‐Fuel‐Cell (HAE‐FC) units is analyzed relative to conventional setups. Controller parameters for TIDF, 2DOF‐TIDF, and AF‐2DOF‐TIDF are optimized using the Skill Optimization Algorithm (SOA). Simulation results demonstrate that the proposed controller significantly enhances dynamic response, reducing overshoot, damping oscillations, and shortening settling times. The integration of a Unified Power Flow Controller (UPFC) further enhances frequency and power stability. Sensitivity analyses confirm the robustness of the proposed controller under varying loads and parameter uncertainties, with an average reduction of 68.4% in oscillation amplitude achieved.

Authors

Institutions

Publication Details

Journal
Energy Science & Engineering
Published
2025-12-12
DOI
https://doi.org/10.1002/ese3.70389
Citations
1
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized Asymmetrical Fuzzy‐2DOFTIDF Controller for LFC of Three‐Area Multi‐Sources Interconnected Power System Along With HAE‐FC and UPFC Using a New SOA Algorithm

Getaneh Mesfin Meseret
1 citations
Energy Science & Engineering
Frequency Control in Power Systems
0.73
article

Optimized Asymmetrical Fuzzy‐2DOFTIDF Controller for LFC of Three‐Area Multi‐Sources Interconnected Power System Along With HAE‐FC and UPFC Using a New SOA Algorithm

Getaneh Mesfin Meseret
article en
1 citations

Abstract

ABSTRACT The increasing complexity and scale of modern power systems, combined with fluctuations in demand, modeling uncertainties, evolving network configurations, and time‐varying characteristics, make load frequency control (LFC) increasingly challenging. Large frequency deviations can disrupt electric clock synchronization, alter AC motor speeds, affect magnetizing currents in transformers and induction motors, and impair the coordinated operation of systems. Conventional control methods often fail to effectively manage these uncertainties. This study evaluates LFC performance in a multi‐area, multi‐source interconnected power system using a novel Asymmetrical‐Fuzzy‐based Two‐Degree‐of‐freedom Tilt‐Integral‐Derivative Controller with Low‐Pass‐Filter (AF‐2DOF‐TIDF) as a secondary control mechanism. The system comprises three unequal areas that integrate hybrid‐thermal and hydropower plants, representing real‐world asymmetries in capacity, inertia, and interconnections. The dynamic influence of Hydrogen‐Aqua‐Electrolyzer‐Fuel‐Cell (HAE‐FC) units is analyzed relative to conventional setups. Controller parameters for TIDF, 2DOF‐TIDF, and AF‐2DOF‐TIDF are optimized using the Skill Optimization Algorithm (SOA). Simulation results demonstrate that the proposed controller significantly enhances dynamic response, reducing overshoot, damping oscillations, and shortening settling times. The integration of a Unified Power Flow Controller (UPFC) further enhances frequency and power stability. Sensitivity analyses confirm the robustness of the proposed controller under varying loads and parameter uncertainties, with an average reduction of 68.4% in oscillation amplitude achieved.

Energy Science & EngineeringVol. 14(2)
AMET University (IN), Debre Tabor University (ET)
Openalex Percentile: Top 21%
Frequency Control in Power Systems
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimized Asymmetrical Fuzzy‐2DOFTIDF Controller for LFC of Three‐Area Multi‐Sources Interconnected Power System Along With HAE‐FC and UPFC Using a New SOA Algorithm — Getaneh Mesfin Meseret · Energy Science & Engineering (2025) | TGRS Research Map | TGRS