Precise Determination of the Band‐Broadening Function for the Size‐Exclusion Chromatography using Multi‐Angle Light Scattering and Mass Spectrometric Measurements on Polymers

Size-exclusion chromatography (SEC) equipped with refractive index (RI) and multi-angle light scattering (MALS) detectors was carried out on a polystyrene (PS) sample with the weight-average molecular weight 2.07 ×€10<sup>4</sup> along with the matrix-assisted laser desorption flight time mass spectrometry (MALDI-TOF-MS). The MALDI-TO-MS result was corrected by the relative sensitivity, which was found to decay exponentially with the molecular weight. Exchanging the elution volume for molecular weight by the calibration relation, the molecular-weight distribution (MWD) curves were obtained from the chromatograms. The MWD curve determined by the SEC chromatogram was much broader than that obtained by MALS and MALDI-TOF-MS because of the peak-broadening effect. Based on the MWD determined by MALDI-TOF-MS, the RI chromatogram was closely described by the calculated values using the Gaussian function. Based on the results of the PS sample, RI and MALS data of polyethylene oxide samples in water were analyzed using the exponentially modified Gaussian equation.

Authors

Institutions

Publication Details

Journal
Macromolecular Rapid Communications
Published
2025-12-12
DOI
https://doi.org/10.1002/marc.202500706
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Precise Determination of the Band‐Broadening Function for the Size‐Exclusion Chromatography using Multi‐Angle Light Scattering and Mass Spectrometric Measurements on Polymers

Yasushi Kondo, Yo Nakamura
Macromolecular Rapid Communications
Analytical Chemistry and Chromatography
article

Precise Determination of the Band‐Broadening Function for the Size‐Exclusion Chromatography using Multi‐Angle Light Scattering and Mass Spectrometric Measurements on Polymers

Yasushi Kondo, Yo Nakamura
article en

Abstract

Size-exclusion chromatography (SEC) equipped with refractive index (RI) and multi-angle light scattering (MALS) detectors was carried out on a polystyrene (PS) sample with the weight-average molecular weight 2.07 ×€10<sup>4</sup> along with the matrix-assisted laser desorption flight time mass spectrometry (MALDI-TOF-MS). The MALDI-TO-MS result was corrected by the relative sensitivity, which was found to decay exponentially with the molecular weight. Exchanging the elution volume for molecular weight by the calibration relation, the molecular-weight distribution (MWD) curves were obtained from the chromatograms. The MWD curve determined by the SEC chromatogram was much broader than that obtained by MALS and MALDI-TOF-MS because of the peak-broadening effect. Based on the MWD determined by MALDI-TOF-MS, the RI chromatogram was closely described by the calculated values using the Gaussian function. Based on the results of the PS sample, RI and MALS data of polyethylene oxide samples in water were analyzed using the exponentially modified Gaussian equation.

Macromolecular Rapid Communications
Kyoto University (JP)
Openalex Percentile: Top 64%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Precise Determination of the Band‐Broadening Function for the Size‐Exclusion Chromatography using Multi‐Angle Light Scattering and Mass Spectrometric Measurements on Polymers — Yasushi Kondo, Yo Nakamura · Macromolecular Rapid Communications (2025) | TGRS Research Map | TGRS