Direct measurement of relative stopping power maps of prosthesis devices and synthetic materials by proton computed tomography

<i>Objective.</i>Treatment planning in proton therapy requires an accurate estimation of stopping power ratio relative to water (SPR) maps. Presently, about 4% of patients submitted to radiotherapy treatments have metallic implants, which are responsible for an incorrect determination of SPRs in prostheses and surrounding regions. This study presents the first application of the proton computed tomography (pCT) technique, able to directly measure SPRs maps, on complex metallic implants.<i>Approach.</i>A homogeneous Ti6Al4V alloy sample, a set of metallic devices used for prostheses and an intra-vertebral titanium alloy implant have been inspected, by means of a prototype pCT system with a 5 × 20 cm<sup>2</sup>field-of-view (FoV) developed by INFN Firenze (Italy), under a proton beam at Trento Proton Therapy Centre (APSS, Trento, Italy). For comparison, a Multi Layer Ionization Chamber (MLIC) has been used to independently determine the SPR mean value of the Ti6Al4V alloy sample.<i>Main Results.</i>Tomographic reconstructions of all devices and materials have been performed and SPR maps have been obtained. All pCT images and profiles, even of metallic components, are characterized by negligible artifacts. The fine spatial resolution of our pCT system, about 0.7 lp mm<sup>-1</sup>, allowed us to resolve details within a millimeter scale. The internal grid of the meshed cage as well as details of the screws' head of the intra-vertebral titanium alloy implant are clearly visible. The SPR of the Ti6Al4V alloy sample measured with pCT, 3.14 ± 0.02, compares well with what was measured by MLIC: 3.17 ± 0.02.<i>Significance.</i>This study presents the first application of the pCT methodology to directly measure SPR maps of complex metal prostheses. The ability of pCT to correctly determine mean SPR values has been experimentally demonstrated. Furthermore, this technique was shown to reconstruct complex metal structures at the millimeter scale with negligible artifacts.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-12-12
DOI
https://doi.org/10.1088/1361-6560/ae2c38
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct measurement of relative stopping power maps of prosthesis devices and synthetic materials by proton computed tomography

Enrico Verroi, M. Scaringella, Stefano Lorentini, Francesco Tommasino et al.
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
article

Direct measurement of relative stopping power maps of prosthesis devices and synthetic materials by proton computed tomography

Enrico Verroi, M. Scaringella, Stefano Lorentini, Francesco Tommasino, M. Bruzzi, Roberto Righetto, Elena Fogazzi, C. Civinini, Francesco Fracchiolla
article en

Abstract

<i>Objective.</i>Treatment planning in proton therapy requires an accurate estimation of stopping power ratio relative to water (SPR) maps. Presently, about 4% of patients submitted to radiotherapy treatments have metallic implants, which are responsible for an incorrect determination of SPRs in prostheses and surrounding regions. This study presents the first application of the proton computed tomography (pCT) technique, able to directly measure SPRs maps, on complex metallic implants.<i>Approach.</i>A homogeneous Ti6Al4V alloy sample, a set of metallic devices used for prostheses and an intra-vertebral titanium alloy implant have been inspected, by means of a prototype pCT system with a 5 × 20 cm<sup>2</sup>field-of-view (FoV) developed by INFN Firenze (Italy), under a proton beam at Trento Proton Therapy Centre (APSS, Trento, Italy). For comparison, a Multi Layer Ionization Chamber (MLIC) has been used to independently determine the SPR mean value of the Ti6Al4V alloy sample.<i>Main Results.</i>Tomographic reconstructions of all devices and materials have been performed and SPR maps have been obtained. All pCT images and profiles, even of metallic components, are characterized by negligible artifacts. The fine spatial resolution of our pCT system, about 0.7 lp mm<sup>-1</sup>, allowed us to resolve details within a millimeter scale. The internal grid of the meshed cage as well as details of the screws' head of the intra-vertebral titanium alloy implant are clearly visible. The SPR of the Ti6Al4V alloy sample measured with pCT, 3.14 ± 0.02, compares well with what was measured by MLIC: 3.17 ± 0.02.<i>Significance.</i>This study presents the first application of the pCT methodology to directly measure SPR maps of complex metal prostheses. The ability of pCT to correctly determine mean SPR values has been experimentally demonstrated. Furthermore, this technique was shown to reconstruct complex metal structures at the millimeter scale with negligible artifacts.

Physics in Medicine and BiologyVol. 71(1)
Istituto Nazionale di Fisica Nucleare (IT), University of Trento (IT), Istituto Nazionale di Fisica Nucleare, Trento Institute for Fundamental Physics And Applications (IT), Provincia Autonoma di Trento (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Firenze (IT), University of Florence (IT)
Openalex Percentile: Top 41%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.