DIRECT ELEMENTAL ANALYSIS OF WINES BY MICROWAVE INDUCED PLASMA ATOMIC EMISSION SPECTROMETRY AND INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY

Methods for the direct analysis of table wines by microwave induced plasma atomic emission spectrometry (MIP-AES) and inductively coupled plasma atomic emission spectrometry (ICP-AES) using matrix matching are presented. K, Na, Ca, Mg, B, Si, Al, Fe, Cu, Mn, Ba, Sr, Li, Zn are quantitatively determined from one dilution with an error of no more than 10% ( = 2). The range of constancy of analytical signals was determined when varying the concentrations of potassium, alcohol, and sucrose in MIP-AES analysis. It was shown that there is no decrease in the background signal when replacing nitrogen with air in the auxiliary flow, and that analytical characteristics improve when using yttrium as an internal standard in MIP-AES. The results were confirmed by capillary zone electrophoresis, the spiking method, and comparison of ICP-AES and MIP-AES analysis results.

Authors

Publication Details

Journal
Журнал аналитической химии / Journal of Analytical Chemistry
Published
2025-01-01
DOI
https://doi.org/10.7868/s3034512x25120068
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DIRECT ELEMENTAL ANALYSIS OF WINES BY MICROWAVE INDUCED PLASMA ATOMIC EMISSION SPECTROMETRY AND INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY

V.A. Trunova
Журнал аналитической химии / Journal of Analytical Chemistry
Analytical chemistry methods development
article

DIRECT ELEMENTAL ANALYSIS OF WINES BY MICROWAVE INDUCED PLASMA ATOMIC EMISSION SPECTROMETRY AND INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY

V.A. Trunova
article en

Abstract

Methods for the direct analysis of table wines by microwave induced plasma atomic emission spectrometry (MIP-AES) and inductively coupled plasma atomic emission spectrometry (ICP-AES) using matrix matching are presented. K, Na, Ca, Mg, B, Si, Al, Fe, Cu, Mn, Ba, Sr, Li, Zn are quantitatively determined from one dilution with an error of no more than 10% ( = 2). The range of constancy of analytical signals was determined when varying the concentrations of potassium, alcohol, and sucrose in MIP-AES analysis. It was shown that there is no decrease in the background signal when replacing nitrogen with air in the auxiliary flow, and that analytical characteristics improve when using yttrium as an internal standard in MIP-AES. The results were confirmed by capillary zone electrophoresis, the spiking method, and comparison of ICP-AES and MIP-AES analysis results.

Журнал аналитической химии / Journal of Analytical ChemistryVol. 80(12)
Openalex Percentile: Top 58%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.