IMMUNOCHROMATOGRAPHIC TEST SYSTEM FOR THE DETERMINATION OF BISPHENOL A WITH MAGNETIC CONCENTRATION

Bisphenol A (BPA) is widely used as a hardener in the production of plastics. However, its release and circulation in ecosystems lead to contamination of drinking water and food products, accompanied by a negative impact on human health, primarily on the endocrine system. In this regard, there is a need for simple and efficient BPA monitoring tools. The paper presents a combination of two approaches for this purpose – the use of magnetic particles (MP) as an antibody carrier and immunochromatographic test strips for recording labeled immune complexes. The visual detection limit of BPA was 10 μg/ml, the instrumental limit was 55 ng/ml, the working range of quantitative determination was 0.1–10 μg/ml. The efficiency of using the MP conjugate for analyte concentration was demonstrated, allowing the detection limit to be reduced by ~200 times. The developed ICA is suitable for qualitative control of the presence and quantitative determination of BPA content in drinking and natural water samples (the detection rate is in the range of 94–106%).

Authors

Publication Details

Journal
Журнал аналитической химии / Journal of Analytical Chemistry
Published
2025-01-01
DOI
https://doi.org/10.7868/s3034512x25120074
Primary Topic
Effects and risks of endocrine disrupting chemicals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IMMUNOCHROMATOGRAPHIC TEST SYSTEM FOR THE DETERMINATION OF BISPHENOL A WITH MAGNETIC CONCENTRATION

Nadezhda A. Taranova
Журнал аналитической химии / Journal of Analytical Chemistry
Effects and risks of endocrine disrupting chemicals
article

IMMUNOCHROMATOGRAPHIC TEST SYSTEM FOR THE DETERMINATION OF BISPHENOL A WITH MAGNETIC CONCENTRATION

Nadezhda A. Taranova
article en

Abstract

Bisphenol A (BPA) is widely used as a hardener in the production of plastics. However, its release and circulation in ecosystems lead to contamination of drinking water and food products, accompanied by a negative impact on human health, primarily on the endocrine system. In this regard, there is a need for simple and efficient BPA monitoring tools. The paper presents a combination of two approaches for this purpose – the use of magnetic particles (MP) as an antibody carrier and immunochromatographic test strips for recording labeled immune complexes. The visual detection limit of BPA was 10 μg/ml, the instrumental limit was 55 ng/ml, the working range of quantitative determination was 0.1–10 μg/ml. The efficiency of using the MP conjugate for analyte concentration was demonstrated, allowing the detection limit to be reduced by ~200 times. The developed ICA is suitable for qualitative control of the presence and quantitative determination of BPA content in drinking and natural water samples (the detection rate is in the range of 94–106%).

Журнал аналитической химии / Journal of Analytical ChemistryVol. 80(12)
Openalex Percentile: Top 51%
Effects and risks of endocrine disrupting chemicals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

IMMUNOCHROMATOGRAPHIC TEST SYSTEM FOR THE DETERMINATION OF BISPHENOL A WITH MAGNETIC CONCENTRATION — Nadezhda A. Taranova · Журнал аналитической химии / Journal of Analytical Chemistry (2025) | TGRS Research Map | TGRS