Early prediction of tablet defects during pan coating

The appearance of a tablet is a critical quality attribute that can be directly evaluated by patients. During tablet manufacturing, mechanical stress may lead to visual defects, such as edge chipping, the prediction of which remains a major challenge, particularly during technology transfer or scale-up processes. This study aimed to evaluate whether the number and severity of defects could be predicted under two mechanical stress environments: pan coating and friabilator testing. A breakage model was calibrated using drop tests with two placebo formulations: mannitol:microcrystalline cellulose (7:3) and microcrystalline cellulose:anhydrous dibasic calcium phosphate (7:3), both at target tensile strengths of 1.5-2.5 MPa. Discrete element method (DEM) simulations were used to estimate the collision velocities and frequencies in the coating pan, enabling defect prediction using the breakage model. One verification run was performed using the mannitol:MCC 7:3 formulation at 2.0 MPa, which was also used to predict the tablet appearance in the friabilator. The model accurately predicted the severity of defects (Classes I-III, where I is the least and III the most severe defect) in the coating trial but underestimated the number of Class I defects. The numerical predictions made by the model are exponentially affected by inaccuracies in the calibration of model parameters, particularly for small damage. Visual differences between tablets with equal mass loss in the friabilator and pan coater also suggest that wear from low-force collisions contributed to damage during the coating process. In contrast, the number of appearance defects was overpredicted in the friabilator, highlighting the model's limitations in systems with frequent collisions. Overall, with careful calibration and under conditions with few defect-causing events, the model can provide useful guidance for defect prediction.

Authors

Institutions

Publication Details

Journal
European Journal of Pharmaceutical Sciences
Published
2025-12-12
DOI
https://doi.org/10.1016/j.ejps.2025.107414
Primary Topic
Granular flow and fluidized beds
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Early prediction of tablet defects during pan coating

Pirjo Tajarobi, Håkan Wikström, Jarkko Ketolainen, Joona Sorjonen et al.
European Journal of Pharmaceutical Sciences
Granular flow and fluidized beds
article

Early prediction of tablet defects during pan coating

Pirjo Tajarobi, Håkan Wikström, Jarkko Ketolainen, Joona Sorjonen, Luis Martín de Juan
article en

Abstract

The appearance of a tablet is a critical quality attribute that can be directly evaluated by patients. During tablet manufacturing, mechanical stress may lead to visual defects, such as edge chipping, the prediction of which remains a major challenge, particularly during technology transfer or scale-up processes. This study aimed to evaluate whether the number and severity of defects could be predicted under two mechanical stress environments: pan coating and friabilator testing. A breakage model was calibrated using drop tests with two placebo formulations: mannitol:microcrystalline cellulose (7:3) and microcrystalline cellulose:anhydrous dibasic calcium phosphate (7:3), both at target tensile strengths of 1.5-2.5 MPa. Discrete element method (DEM) simulations were used to estimate the collision velocities and frequencies in the coating pan, enabling defect prediction using the breakage model. One verification run was performed using the mannitol:MCC 7:3 formulation at 2.0 MPa, which was also used to predict the tablet appearance in the friabilator. The model accurately predicted the severity of defects (Classes I-III, where I is the least and III the most severe defect) in the coating trial but underestimated the number of Class I defects. The numerical predictions made by the model are exponentially affected by inaccuracies in the calibration of model parameters, particularly for small damage. Visual differences between tablets with equal mass loss in the friabilator and pan coater also suggest that wear from low-force collisions contributed to damage during the coating process. In contrast, the number of appearance defects was overpredicted in the friabilator, highlighting the model's limitations in systems with frequent collisions. Overall, with careful calibration and under conditions with few defect-causing events, the model can provide useful guidance for defect prediction.

European Journal of Pharmaceutical SciencesVol. 217
University of Eastern Finland (FI), AstraZeneca (Netherlands) (NL), AstraZeneca (Poland) (PL)
Openalex Percentile: Top 59%
Granular flow and fluidized beds
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.