Automation of Detector Array Design for Baggage X-Ray Scanners

Geometric inaccuracies in the design of X-ray baggage scanners can lead to significant image artifacts, such as banding and discontinuities, which compromise security screening effectiveness. Although comprehensive commercial solutions are available, constructing a custom X-ray scanner requires the precise alignment of detector arrays. This is a complex and time-consuming process when performed manually. The core of the proposed method is a computational model that calculates the optimal position and orientation for each detector card based on user-defined scanner dimensions and hardware parameters. To validate the geometry created with this method, its performance was compared against flat and arc-shaped geometries. The results demonstrate that the proposed method successfully generates geometries that produce continuous and artifact-free images. The study concludes that the developed software tool provides a robust and practical solution, significantly simplifying the complex task of scanner construction and accelerating the development of reliable, custom X-ray inspection systems.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-12-12
DOI
https://doi.org/10.3390/s25247550
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automation of Detector Array Design for Baggage X-Ray Scanners

Krzysztof Dmitruk
Sensors
Advanced X-ray and CT Imaging
article

Automation of Detector Array Design for Baggage X-Ray Scanners

Krzysztof Dmitruk
article en

Abstract

Geometric inaccuracies in the design of X-ray baggage scanners can lead to significant image artifacts, such as banding and discontinuities, which compromise security screening effectiveness. Although comprehensive commercial solutions are available, constructing a custom X-ray scanner requires the precise alignment of detector arrays. This is a complex and time-consuming process when performed manually. The core of the proposed method is a computational model that calculates the optimal position and orientation for each detector card based on user-defined scanner dimensions and hardware parameters. To validate the geometry created with this method, its performance was compared against flat and arc-shaped geometries. The results demonstrate that the proposed method successfully generates geometries that produce continuous and artifact-free images. The study concludes that the developed software tool provides a robust and practical solution, significantly simplifying the complex task of scanner construction and accelerating the development of reliable, custom X-ray inspection systems.

SensorsVol. 25(24)
Maria Curie-Skłodowska University (PL)
Openalex Percentile: Top 61%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.