Using induced charge detection to quantify the net charge of microdroplets within a quadrupole electrodynamic trap

Precise and accurate charge measurements on microdroplets are essential for understanding the role of charge in modulating microdroplet chemistry, including reaction kinetics, ion distribution, and interfacial dynamics. Despite the availability of various charge measurement techniques, existing contactless techniques either lack the sensitivity to accurately detect charges with ∼1 fC precision or lack the ability to measure charge on micron-sized particles, leaving a significant gap in the field. Here, a new technique is presented to directly measure the net charge of microdroplets exiting a quadrupole electrodynamic trap (QET) using induced charge detection. With this method, the charge droplets induce on a cylindrical electrode (Qinduced) is detected using a homebuilt charge sensitive pre-amplifier (CSP). The long time constant of the CSP (1.02 ± 0.01 s-1) facilitates accurate measurement of Qinduced on slow-moving microdroplets that interact with the detection electrode for up to 100s of ms. The new charge detection method is validated by comparing Qinduced with the charge of droplets measured using a Faraday cup (QFaraday cup) for roughly 2900 droplets with different net charges, sizes, and velocities. Regardless of droplet properties, Qinduced closely correlates with QFaraday cup with absolute differences averaging <5 fC (i.e., 1% accuracy). While the charge detection system is coupled to a QET, it could easily be adapted for other droplet-based measurements (e.g., droplet train experiments). Ultimately, the induced charge detection system presented here will support future studies exploring how charge influences the physical and chemical processing of microdroplets, such as understanding how charge can drive accelerated chemistry in microdroplets.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-12-01
DOI
https://doi.org/10.1063/5.0294542
Primary Topic
Electrohydrodynamics and Fluid Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using induced charge detection to quantify the net charge of microdroplets within a quadrupole electrodynamic trap

Michael I. Jacobs, Firoz Ahmed
Review of Scientific Instruments
Electrohydrodynamics and Fluid Dynamics
article

Using induced charge detection to quantify the net charge of microdroplets within a quadrupole electrodynamic trap

Michael I. Jacobs, Firoz Ahmed
article en

Abstract

Precise and accurate charge measurements on microdroplets are essential for understanding the role of charge in modulating microdroplet chemistry, including reaction kinetics, ion distribution, and interfacial dynamics. Despite the availability of various charge measurement techniques, existing contactless techniques either lack the sensitivity to accurately detect charges with ∼1 fC precision or lack the ability to measure charge on micron-sized particles, leaving a significant gap in the field. Here, a new technique is presented to directly measure the net charge of microdroplets exiting a quadrupole electrodynamic trap (QET) using induced charge detection. With this method, the charge droplets induce on a cylindrical electrode (Qinduced) is detected using a homebuilt charge sensitive pre-amplifier (CSP). The long time constant of the CSP (1.02 ± 0.01 s-1) facilitates accurate measurement of Qinduced on slow-moving microdroplets that interact with the detection electrode for up to 100s of ms. The new charge detection method is validated by comparing Qinduced with the charge of droplets measured using a Faraday cup (QFaraday cup) for roughly 2900 droplets with different net charges, sizes, and velocities. Regardless of droplet properties, Qinduced closely correlates with QFaraday cup with absolute differences averaging <5 fC (i.e., 1% accuracy). While the charge detection system is coupled to a QET, it could easily be adapted for other droplet-based measurements (e.g., droplet train experiments). Ultimately, the induced charge detection system presented here will support future studies exploring how charge influences the physical and chemical processing of microdroplets, such as understanding how charge can drive accelerated chemistry in microdroplets.

Review of Scientific InstrumentsVol. 96(12)
Texas State University (US)
Openalex Percentile: Top 60%
Electrohydrodynamics and Fluid Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Using induced charge detection to quantify the net charge of microdroplets within a quadrupole electrodynamic trap — Michael I. Jacobs, Firoz Ahmed · Review of Scientific Instruments (2025) | TGRS Research Map | TGRS