Novel technique of innerbranch stent-grafts for common iliac artery aneurysm ensured blood flow to the pelvic region and lower extremities

We report a technique to preserve the internal iliac artery (IIA) using a physician-modified contralateral limb (PMCL) with an inner branch stent-graft (IBS) for patients with common iliac artery aneurysms not suitable for commercially-available iliac branch devices (cIBDs). A fenestration was created in the tapered or 13 mm segment of an Endurant II contralateral limb, and an IBS-2 mm larger in diameter than the fenestration-was inserted and deployed with 15-20 mm inside the PMCL and 5 mm externally. The IBS was fixed at three points in parallel to the limb. A preloaded wire was inserted, and the system reloaded and implanted. Two patients were treated using this method, with the IIA stent-graft deployed into the superior gluteal artery. One had a fenestration in the tapered segment, the other in the 13 mm segment. Follow-up computed tomography showed no endoleaks and satisfactory pelvic perfusion in both cases, with no complications. This technique maintains pelvic and lower extremity blood flow, ensures graft stability, and allows future endovascular reintervention. It may be a valuable alternative for patients for whom cIBDs are not indicated.Clinical ImpactPreserving the internal iliac artery is essential, but maintaining adequate lower-extremity perfusion during treatment of common iliac artery aneurysms is equally important. Our physician-modified contralateral limb with an inner branch stent-graft successfully achieved both goals in two cases. The construct also maintained its shape without deformation and resisted migration, even when additional endovascular procedures involved the inner branch stent-graft.

Authors

Institutions

Publication Details

Journal
Journal of Endovascular Therapy
Published
2025-12-12
DOI
https://doi.org/10.1177/15266028251397301
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel technique of innerbranch stent-grafts for common iliac artery aneurysm ensured blood flow to the pelvic region and lower extremities

Manabu Misu, Hideyuki Shimizu, Kenichi Hashizume, Hiroaki Kaneyama et al.
Journal of Endovascular Therapy
Aortic aneurysm repair treatments
article

Novel technique of innerbranch stent-grafts for common iliac artery aneurysm ensured blood flow to the pelvic region and lower extremities

Manabu Misu, Hideyuki Shimizu, Kenichi Hashizume, Hiroaki Kaneyama, Koki Ikebata, Takashi Hashimoto, Kiyoshi Koizumi
article en

Abstract

We report a technique to preserve the internal iliac artery (IIA) using a physician-modified contralateral limb (PMCL) with an inner branch stent-graft (IBS) for patients with common iliac artery aneurysms not suitable for commercially-available iliac branch devices (cIBDs). A fenestration was created in the tapered or 13 mm segment of an Endurant II contralateral limb, and an IBS-2 mm larger in diameter than the fenestration-was inserted and deployed with 15-20 mm inside the PMCL and 5 mm externally. The IBS was fixed at three points in parallel to the limb. A preloaded wire was inserted, and the system reloaded and implanted. Two patients were treated using this method, with the IIA stent-graft deployed into the superior gluteal artery. One had a fenestration in the tapered segment, the other in the 13 mm segment. Follow-up computed tomography showed no endoleaks and satisfactory pelvic perfusion in both cases, with no complications. This technique maintains pelvic and lower extremity blood flow, ensures graft stability, and allows future endovascular reintervention. It may be a valuable alternative for patients for whom cIBDs are not indicated.Clinical ImpactPreserving the internal iliac artery is essential, but maintaining adequate lower-extremity perfusion during treatment of common iliac artery aneurysms is equally important. Our physician-modified contralateral limb with an inner branch stent-graft successfully achieved both goals in two cases. The construct also maintained its shape without deformation and resisted migration, even when additional endovascular procedures involved the inner branch stent-graft.

Journal of Endovascular Therapy
Keio University (JP), Ashikaga Red Cross Hospital (JP)
Openalex Percentile: Top 42%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.