Chronic Infective Endocarditis Linked to Staphylococcus epidermidis Infection of a Pacemaker Lead: A Case Report

The diagnosis and management of pacemaker-related infective endocarditis present significant challenges, with limited available data. Accurately attributing a systemic infection to pacemaker endocarditis can be difficult, particularly in identifying vegetations and obtaining positive blood cultures from patients who have undergone non-specific antibiotic therapy. Moreover, such infections may manifest long after pacemaker implantation. Herein, we present a male patient in his 70s, with a history of pacemaker placement, who was admitted with a three-month history of fever and chills, having already completed two courses of empirical antibiotics prior to admission. Upon hospital admission, he was treated for an infection of unknown origin with intravenous antibiotics. Initial laboratory evaluations indicated leucocytosis and elevated C-reactive protein levels; however, blood cultures and infectious serologies returned normal results. A CT scan of the abdomen and pelvis was deemed unremarkable, and transthoracic echocardiography (TTE) also yielded normal findings. The empirical antibiotic regimen was discontinued, leading to three sets of blood cultures being subsequently positive for coagulase-negative <i>Staphylococcus epidermidis</i>. A transoesophageal echocardiography (TOE) was performed, revealing vegetation on the pacemaker lead. The patient received a triple antibiotic therapy and underwent device removal; subsequent blood cultures were negative following a four-week antibiotic course. A new pacemaker was implanted, and the patient has since remained asymptomatic. This case illustrates that coagulase-negative <i>Staphylococcus epidermidis</i> can infect pacemaker leads even long after installation, potentially leading to an indolent course of infective endocarditis that is difficult to diagnose and manage. Consequently, clinicians should maintain a high index of suspicion for pacemaker infective endocarditis in patients presenting with prolonged fever.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-12-12
DOI
https://doi.org/10.7759/cureus.99028
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Chronic Infective Endocarditis Linked to Staphylococcus epidermidis Infection of a Pacemaker Lead: A Case Report

Osama Abdalla, Dilrukshi K. Ekanayake, Ghada Idris, Laila Khallaf et al.
Cureus
Cardiac pacing and defibrillation studies
article

Chronic Infective Endocarditis Linked to Staphylococcus epidermidis Infection of a Pacemaker Lead: A Case Report

Osama Abdalla, Dilrukshi K. Ekanayake, Ghada Idris, Laila Khallaf, Charlotte Adjepon
article en

Abstract

The diagnosis and management of pacemaker-related infective endocarditis present significant challenges, with limited available data. Accurately attributing a systemic infection to pacemaker endocarditis can be difficult, particularly in identifying vegetations and obtaining positive blood cultures from patients who have undergone non-specific antibiotic therapy. Moreover, such infections may manifest long after pacemaker implantation. Herein, we present a male patient in his 70s, with a history of pacemaker placement, who was admitted with a three-month history of fever and chills, having already completed two courses of empirical antibiotics prior to admission. Upon hospital admission, he was treated for an infection of unknown origin with intravenous antibiotics. Initial laboratory evaluations indicated leucocytosis and elevated C-reactive protein levels; however, blood cultures and infectious serologies returned normal results. A CT scan of the abdomen and pelvis was deemed unremarkable, and transthoracic echocardiography (TTE) also yielded normal findings. The empirical antibiotic regimen was discontinued, leading to three sets of blood cultures being subsequently positive for coagulase-negative <i>Staphylococcus epidermidis</i>. A transoesophageal echocardiography (TOE) was performed, revealing vegetation on the pacemaker lead. The patient received a triple antibiotic therapy and underwent device removal; subsequent blood cultures were negative following a four-week antibiotic course. A new pacemaker was implanted, and the patient has since remained asymptomatic. This case illustrates that coagulase-negative <i>Staphylococcus epidermidis</i> can infect pacemaker leads even long after installation, potentially leading to an indolent course of infective endocarditis that is difficult to diagnose and manage. Consequently, clinicians should maintain a high index of suspicion for pacemaker infective endocarditis in patients presenting with prolonged fever.

CureusVol. 17(12)
Shrewsbury and Telford Hospital NHS Trust (GB)
Openalex Percentile: Top 43%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.