Beam collimator of electrostatic septum for high-intensity heavy-ion accelerator facility booster

The dynamic vacuum effect is the primary limitation of beam intensity in high-intensity heavy-ion synchrotrons. Although the dynamic vacuum effect in the arc section is mitigated effectively by the beam collimators, the gas desorption induced by injection beam loss occurring in the injection electrostatic septum (ESi) is still an unresolved issue. In addition, the gas desorption is enhanced due to some special mechanisms, including the ultrafast beam loss process, multiple traversals of wire surfaces, and high-voltage breakdown. Mitigating the dynamic vacuum effect in the ESi is a critical approach to achieve a higher beam intensity. Therefore, a novel ES collimator is proposed to reduce beam deposition on the septum. Dynamic simulation of the dual-plane painting injection of BRing reveals the excellent performance of this scheme by a tenfold reduction in beam loss. The features associated with collimation efficiency and structure optimization are analyzed in detail.

Authors

Institutions

Publication Details

Journal
Physical Review Accelerators and Beams
Published
2025-10-09
DOI
https://doi.org/10.1103/83jq-vh5k
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beam collimator of electrostatic septum for high-intensity heavy-ion accelerator facility booster

Karl J. Friston
Physical Review Accelerators and Beams
Particle accelerators and beam dynamics
article

Beam collimator of electrostatic septum for high-intensity heavy-ion accelerator facility booster

Karl J. Friston
article en

Abstract

The dynamic vacuum effect is the primary limitation of beam intensity in high-intensity heavy-ion synchrotrons. Although the dynamic vacuum effect in the arc section is mitigated effectively by the beam collimators, the gas desorption induced by injection beam loss occurring in the injection electrostatic septum (ESi) is still an unresolved issue. In addition, the gas desorption is enhanced due to some special mechanisms, including the ultrafast beam loss process, multiple traversals of wire surfaces, and high-voltage breakdown. Mitigating the dynamic vacuum effect in the ESi is a critical approach to achieve a higher beam intensity. Therefore, a novel ES collimator is proposed to reduce beam deposition on the septum. Dynamic simulation of the dual-plane painting injection of BRing reveals the excellent performance of this scheme by a tenfold reduction in beam loss. The features associated with collimation efficiency and structure optimization are analyzed in detail.

Physical Review Accelerators and BeamsVol. 29(2)
Institute of Modern Physics (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 49%
Particle accelerators and beam dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Beam collimator of electrostatic septum for high-intensity heavy-ion accelerator facility booster — Karl J. Friston · Physical Review Accelerators and Beams (2025) | TGRS Research Map | TGRS