Current and Emerging Technologies for Continuous Intraocular Pressure Monitoring in the Control of Glaucoma Progression: A Scoping Review

<b>Background/Objectives:</b> Glaucoma affects over 70 million people worldwide and is a major cause of irreversible blindness, with elevated intraocular pressure (IOP) as the only modifiable risk factor. Conventional techniques like Goldmann applanation tonometry (GAT) are widely used but cannot provide continuous or nocturnal monitoring, limiting the detection of pressure peaks relevant to disease progression. Emerging technologies, including home-based devices, wearable sensors, such as contact lens-based sensors (CLBS), and implantable biomedical microelectromechanical systems (bioMEMS), offer more comprehensive and continuous assessment of IOP patterns. Thus, this scoping review aimed to map the available evidence on technologies for continuous IOP monitoring, summarizing their performance and agreement with traditional tonometry. <b>Methods</b>: A systematic search of electronic databases was conducted to identify studies published in the last 10 years evaluating self-tonometry devices, CLBS, or implantable systems designed for continuous IOP monitoring. Two reviewers independently screened articles, applied eligibility criteria, charted relevant data, including device characteristics and agreement with GAT, and reported clinical applications. <b>Results</b>: Self-tonometry devices demonstrated generally good agreement with GAT while enabling patients to monitor IOP outside clinical settings. These devices provided valuable information on diurnal and nocturnal IOP fluctuations, especially in individuals with rapid progression or those undergoing postoperative follow-up. BioMEMS-based wearable and implantable sensors showed promise for continuous long-term monitoring and revealed previously unrecognized fluctuation patterns, including activity-related changes. <b>Conclusions</b>: Emerging IOP-monitoring technologies appear to complement standard clinical methods by offering more detailed IOP profiles. Their integration into clinical practice may support individualized risk assessment and improved management of glaucoma progression.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-12-12
DOI
https://doi.org/10.3390/jcm14248795
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Current and Emerging Technologies for Continuous Intraocular Pressure Monitoring in the Control of Glaucoma Progression: A Scoping Review

Susana Ortí-Navarro, Mari Carmen García-Domene, Daniel Monsálvez-Romín, Noelia Martínez-Albert
Journal of Clinical Medicine
Corneal surgery and disorders
article

Current and Emerging Technologies for Continuous Intraocular Pressure Monitoring in the Control of Glaucoma Progression: A Scoping Review

Susana Ortí-Navarro, Mari Carmen García-Domene, Daniel Monsálvez-Romín, Noelia Martínez-Albert
article en

Abstract

<b>Background/Objectives:</b> Glaucoma affects over 70 million people worldwide and is a major cause of irreversible blindness, with elevated intraocular pressure (IOP) as the only modifiable risk factor. Conventional techniques like Goldmann applanation tonometry (GAT) are widely used but cannot provide continuous or nocturnal monitoring, limiting the detection of pressure peaks relevant to disease progression. Emerging technologies, including home-based devices, wearable sensors, such as contact lens-based sensors (CLBS), and implantable biomedical microelectromechanical systems (bioMEMS), offer more comprehensive and continuous assessment of IOP patterns. Thus, this scoping review aimed to map the available evidence on technologies for continuous IOP monitoring, summarizing their performance and agreement with traditional tonometry. <b>Methods</b>: A systematic search of electronic databases was conducted to identify studies published in the last 10 years evaluating self-tonometry devices, CLBS, or implantable systems designed for continuous IOP monitoring. Two reviewers independently screened articles, applied eligibility criteria, charted relevant data, including device characteristics and agreement with GAT, and reported clinical applications. <b>Results</b>: Self-tonometry devices demonstrated generally good agreement with GAT while enabling patients to monitor IOP outside clinical settings. These devices provided valuable information on diurnal and nocturnal IOP fluctuations, especially in individuals with rapid progression or those undergoing postoperative follow-up. BioMEMS-based wearable and implantable sensors showed promise for continuous long-term monitoring and revealed previously unrecognized fluctuation patterns, including activity-related changes. <b>Conclusions</b>: Emerging IOP-monitoring technologies appear to complement standard clinical methods by offering more detailed IOP profiles. Their integration into clinical practice may support individualized risk assessment and improved management of glaucoma progression.

Journal of Clinical MedicineVol. 14(24)
Universitat de València (ES)
Openalex Percentile: Top 45%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.