Numerical and experimental investigation of a novel hybrid indirect-direct evaporative cooling system with enhanced humidity regulation: A case study in hot-humid conditions

Evaporative cooling is a sustainable and cost-effective substitute to the conventional mechanical refrigeration and air conditioning systems. Its widespread application is limited in hot and humid climatic conditions, where such systems exhibit excessive addition of moisture content to supply air. This research presents a hybrid indirect direct evaporative cooling (HIDEC) system, enhanced with a forced-draft cooling tower for water temperature control and a silica-gel desiccant dehumidifier for post-cooling moisture regulation. The 3D HIDEC CFD model comprising the k-ε turbulence model, the heat transfer in fluids model, and the moisture transport interface is developed using COMSOL Multiphysics. It is experimentally validated in real-time composite climatic conditions. The hybrid configuration exhibits an enhanced moisture regulation and cooling stability compared to the conventional IEC/DEC arrangements. The numerical CFD analysis reveals system's optimal operating zones under varying humidity and temperature conditions, offering unique design insights on the high-performance hybrid evaporative cooling systems catering to hot-humid and hot-dry conditions. Parametric analysis of the experimental HIDEC system yields a maximum cooling capacity of 25.4 kW and COP of 24.2 during hot and dry conditions whereas, a maximum cooling capacity of 7.8 kW and COP of 7.1 is observed during hot and humid conditions. • Numerical and experimental analysis on novel HIDEC system integrating cooling tower and post-cooling dehumidification mechanism is presented. • HIDEC system is numerically modelled and experimentally validated during real-time hot-dry and hot-humid conditions. • 3D numerical HIDEC CFD analysis comprises k-ε turbulent flow, heat transfer in fluids and moisture transport models. • Parametric evaluation yields a maximum COP of 24.2 and cooling capacity of 25.4 kW during hot-dry conditions.

Authors

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-12-12
DOI
https://doi.org/10.1016/j.csite.2025.107538
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical and experimental investigation of a novel hybrid indirect-direct evaporative cooling system with enhanced humidity regulation: A case study in hot-humid conditions

Waqas Khalid, Samiul Hasan, Emad Uddin, Hafız Muhammad Ali et al.
Case Studies in Thermal Engineering
Adsorption and Cooling Systems
article

Numerical and experimental investigation of a novel hybrid indirect-direct evaporative cooling system with enhanced humidity regulation: A case study in hot-humid conditions

Waqas Khalid, Samiul Hasan, Emad Uddin, Hafız Muhammad Ali, Ibrahim Khan, Zafeer Atif
article en

Abstract

Evaporative cooling is a sustainable and cost-effective substitute to the conventional mechanical refrigeration and air conditioning systems. Its widespread application is limited in hot and humid climatic conditions, where such systems exhibit excessive addition of moisture content to supply air. This research presents a hybrid indirect direct evaporative cooling (HIDEC) system, enhanced with a forced-draft cooling tower for water temperature control and a silica-gel desiccant dehumidifier for post-cooling moisture regulation. The 3D HIDEC CFD model comprising the k-ε turbulence model, the heat transfer in fluids model, and the moisture transport interface is developed using COMSOL Multiphysics. It is experimentally validated in real-time composite climatic conditions. The hybrid configuration exhibits an enhanced moisture regulation and cooling stability compared to the conventional IEC/DEC arrangements. The numerical CFD analysis reveals system's optimal operating zones under varying humidity and temperature conditions, offering unique design insights on the high-performance hybrid evaporative cooling systems catering to hot-humid and hot-dry conditions. Parametric analysis of the experimental HIDEC system yields a maximum cooling capacity of 25.4 kW and COP of 24.2 during hot and dry conditions whereas, a maximum cooling capacity of 7.8 kW and COP of 7.1 is observed during hot and humid conditions. • Numerical and experimental analysis on novel HIDEC system integrating cooling tower and post-cooling dehumidification mechanism is presented. • HIDEC system is numerically modelled and experimentally validated during real-time hot-dry and hot-humid conditions. • 3D numerical HIDEC CFD analysis comprises k-ε turbulent flow, heat transfer in fluids and moisture transport models. • Parametric evaluation yields a maximum COP of 24.2 and cooling capacity of 25.4 kW during hot-dry conditions.

Case Studies in Thermal EngineeringVol. 77
Openalex Percentile: Top 59%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.