Spiral Vein Graft Reconstruction for an Infected Common Femoral Artery Pseudoaneurysm after Vascular Closure Device and Stent-Graft Failure: A Case Report

Vascular closure devices (VCDs) allow rapid hemostasis after endovascular procedures but may rarely cause pseudoaneurysms or infections. Infected pseudoaneurysms of the common femoral artery (CFA) following VCD use are uncommon, and stent-graft exclusion is discouraged in infected fields and high-motion sites such as the groin. We report a 68-year-old male with end-stage renal disease on hemodialysis who developed an infected CFA pseudoaneurysm after VCD and subsequent stent-graft placement. The lesion was complicated by vancomycin-intermediate <i>Staphylococcus aureus</i> bacteremia and arterial wall destruction. Surgical debridement and excision of the infected stent-graft were followed by autologous spiral vein graft reconstruction using the contralateral great saphenous vein, extending from the external iliac artery to the proximal superficial femoral artery. Postoperative cultures revealed methicillin-resistant <i>Staphylococcus aureus</i> infection. The patient recovered uneventfully with patent reconstruction and no recurrence. This case highlights the risk of VCD-related infections and supports spiral vein grafting as a durable option.

Authors

Institutions

Publication Details

Journal
Vascular Specialist International
Published
2025-12-12
DOI
https://doi.org/10.5758/vsi.250100
Primary Topic
Infectious Aortic and Vascular Conditions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spiral Vein Graft Reconstruction for an Infected Common Femoral Artery Pseudoaneurysm after Vascular Closure Device and Stent-Graft Failure: A Case Report

Eol Choi
Vascular Specialist International
Infectious Aortic and Vascular Conditions
article

Spiral Vein Graft Reconstruction for an Infected Common Femoral Artery Pseudoaneurysm after Vascular Closure Device and Stent-Graft Failure: A Case Report

Eol Choi
article en

Abstract

Vascular closure devices (VCDs) allow rapid hemostasis after endovascular procedures but may rarely cause pseudoaneurysms or infections. Infected pseudoaneurysms of the common femoral artery (CFA) following VCD use are uncommon, and stent-graft exclusion is discouraged in infected fields and high-motion sites such as the groin. We report a 68-year-old male with end-stage renal disease on hemodialysis who developed an infected CFA pseudoaneurysm after VCD and subsequent stent-graft placement. The lesion was complicated by vancomycin-intermediate <i>Staphylococcus aureus</i> bacteremia and arterial wall destruction. Surgical debridement and excision of the infected stent-graft were followed by autologous spiral vein graft reconstruction using the contralateral great saphenous vein, extending from the external iliac artery to the proximal superficial femoral artery. Postoperative cultures revealed methicillin-resistant <i>Staphylococcus aureus</i> infection. The patient recovered uneventfully with patent reconstruction and no recurrence. This case highlights the risk of VCD-related infections and supports spiral vein grafting as a durable option.

Vascular Specialist InternationalVol. 41
Soonchunhyang University (KR), Bucheon University (KR)
Openalex Percentile: Top 41%
Infectious Aortic and Vascular Conditions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.