Electrochemical Detection of NO and Ca2+ during Cold Atmospheric Plasma Treatment of Acute Wounds: Sensor Selectivity and Stability in the Plasma-Bio-System

Cold atmospheric plasmas (CAP) are a versatile tool in medical applications like wound healing. Its therapeutic benefits are partially attributed to the generation of biologically active reactive oxygen and nitrogen species (RONS). Characterization of RONS, however, typically only occurs after treatment. Here we report the first real-time in situ detection of CAP-generated nitric oxide (NO), and the simultaneous detection of cellular calcium ions (Ca²⁺) release using electrochemical sensors during CAP treatment of murine wounds. In vivo, NO rose rapidly within the first minute of CAP treatment but accumulated less overall than in PBS, reflecting reactions with wound-bed targets. In situ measurements revealed nearly double the concentrations of static endpoint assays, underscoring the importance of real-time detection. Ca²⁺ signals displayed transient, burst-like increases, likely due to CAP-induced membrane permeability and as response to oxidative stress. We also investigated the sensitivity, selectivity, and stability of the graphene oxide coated NO sensors and ion-selective Ca²⁺ sensors. Interference studies showed that the NO sensor also responds to H<sub>2</sub>O<sub>2</sub> and NO<sub>2</sub> <sup>-</sup> yet remains most sensitive to NO. Raman microscopy revealed progressive degradation of the graphene oxide layer after only one hour of CAP exposure, drastically reducing sensor currents. Improvements in NO sensor design will enable more accurate measurements for feedback control for plasma-based wound therapies. Ca²⁺ sensors are more robust and retained full functionality after three hours and repeated use providing a reliable diagnostic for immediate biological response. The results establish real-time electrochemical sensing as a powerful approach to monitor CAP-tissue interactions.

Authors

Institutions

Publication Details

Journal
Plasma Chemistry and Plasma Processing
Published
2025-12-12
DOI
https://doi.org/10.1007/s11090-025-10621-9
Primary Topic
Plasma Applications and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Detection of NO and Ca2+ during Cold Atmospheric Plasma Treatment of Acute Wounds: Sensor Selectivity and Stability in the Plasma-Bio-System

Jonathan E. Thomas, Gagana Karkada, Vandana Miller, Suneel Kumar et al.
Plasma Chemistry and Plasma Processing
Plasma Applications and Diagnostics
article

Electrochemical Detection of NO and Ca2+ during Cold Atmospheric Plasma Treatment of Acute Wounds: Sensor Selectivity and Stability in the Plasma-Bio-System

Jonathan E. Thomas, Gagana Karkada, Vandana Miller, Suneel Kumar, Katharina Stapelmann, Duncan Trosan, François Berthiaume, Dnyaneshwari Rananavare, Kristina Pattison, Jason Rainone, Aunic Goodin
article en

Abstract

Cold atmospheric plasmas (CAP) are a versatile tool in medical applications like wound healing. Its therapeutic benefits are partially attributed to the generation of biologically active reactive oxygen and nitrogen species (RONS). Characterization of RONS, however, typically only occurs after treatment. Here we report the first real-time in situ detection of CAP-generated nitric oxide (NO), and the simultaneous detection of cellular calcium ions (Ca²⁺) release using electrochemical sensors during CAP treatment of murine wounds. In vivo, NO rose rapidly within the first minute of CAP treatment but accumulated less overall than in PBS, reflecting reactions with wound-bed targets. In situ measurements revealed nearly double the concentrations of static endpoint assays, underscoring the importance of real-time detection. Ca²⁺ signals displayed transient, burst-like increases, likely due to CAP-induced membrane permeability and as response to oxidative stress. We also investigated the sensitivity, selectivity, and stability of the graphene oxide coated NO sensors and ion-selective Ca²⁺ sensors. Interference studies showed that the NO sensor also responds to H<sub>2</sub>O<sub>2</sub> and NO<sub>2</sub> <sup>-</sup> yet remains most sensitive to NO. Raman microscopy revealed progressive degradation of the graphene oxide layer after only one hour of CAP exposure, drastically reducing sensor currents. Improvements in NO sensor design will enable more accurate measurements for feedback control for plasma-based wound therapies. Ca²⁺ sensors are more robust and retained full functionality after three hours and repeated use providing a reliable diagnostic for immediate biological response. The results establish real-time electrochemical sensing as a powerful approach to monitor CAP-tissue interactions.

Plasma Chemistry and Plasma ProcessingVol. 46(1)
Rutgers, The State University of New Jersey (US), North Carolina State University (US), Thomas Jefferson University (US), Sidney Kimmel Cancer Center (US), Drexel University (US)
Openalex Percentile: Top 45%
Plasma Applications and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.