Finite Element Analysis of Conventional Fixation and <scp>3D</scp> ‐Printed Scaffold Integration for Treating Large Osseous Femoral Defects

This study investigated the biomechanical efficacy of conventional and 3D-printed scaffold-augmented fixation methods for a large 6 cm osseous femoral defect. Finite element analyses were conducted to compare four conventional techniques: single plate, intramedullary nail, combined plate and nail, and double plate. These were then evaluated with the addition of three porous Ti-6Al-4V scaffold designs (Weaire-Phelan, Diamond, and Voronoi) with 70% porosity. Models were subjected to peak physiological loading from gait, simulating a 106 kg patient. Performance was assessed based on implant stress and the volume fraction of the fracture callus experiencing osteogenic strains (0.005%-2.5%). Results showed that conventional single-implant methods were mechanically insufficient; the single plate failed at 20% of the physiological load and the nail at 90%. These methods also produced suboptimal osteogenic environments, with an osteogenic volume fraction < 16%. In contrast, combined conventional methods (plate and nail, double plate) withstood 100% of the load with significantly lower stresses and promoted highly osteogenic environments, with an osteogenic volume fraction > 95%. The integration of 3D-printed scaffolds transformed the single-implant constructs, enabling them to withstand 100% physiological load and increasing their osteogenic volume fraction to over 90%. Scaffolds also substantially reduced stress on the primary implants in all configurations. The plate and nail fixation augmented with a scaffold emerged as the most robust strategy, reducing conventional implant stresses to approximately 140 MPa while maintaining an exceptional osteogenic volume fraction > 99%. These findings highlight the quantitative potential of 3D-printed scaffolds to improve treatment outcomes for large bone defects.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part B Applied Biomaterials
Published
2025-12-01
DOI
https://doi.org/10.1002/jbmb.70010
Citations
1
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite Element Analysis of Conventional Fixation and 3D ‐Printed Scaffold Integration for Treating Large Osseous Femoral Defects

Christos Kalligeros, Athanasios Armakolas, Olga D. Savvidou, Athanasios F. Foukas et al.
1 citations
Journal of Biomedical Materials Research Part B Applied Biomaterials
Orthopaedic implants and arthroplasty
2.01
article

Finite Element Analysis of Conventional Fixation and 3D ‐Printed Scaffold Integration for Treating Large Osseous Femoral Defects

Christos Kalligeros, Athanasios Armakolas, Olga D. Savvidou, Athanasios F. Foukas, Panayiotis J. Papagelopoulos, Vasilios Spitas, Vasilios Gakos, Panagiotis Ntakos, Konstantinos Chouzouris
article en
1 citations

Abstract

This study investigated the biomechanical efficacy of conventional and 3D-printed scaffold-augmented fixation methods for a large 6 cm osseous femoral defect. Finite element analyses were conducted to compare four conventional techniques: single plate, intramedullary nail, combined plate and nail, and double plate. These were then evaluated with the addition of three porous Ti-6Al-4V scaffold designs (Weaire-Phelan, Diamond, and Voronoi) with 70% porosity. Models were subjected to peak physiological loading from gait, simulating a 106 kg patient. Performance was assessed based on implant stress and the volume fraction of the fracture callus experiencing osteogenic strains (0.005%-2.5%). Results showed that conventional single-implant methods were mechanically insufficient; the single plate failed at 20% of the physiological load and the nail at 90%. These methods also produced suboptimal osteogenic environments, with an osteogenic volume fraction < 16%. In contrast, combined conventional methods (plate and nail, double plate) withstood 100% of the load with significantly lower stresses and promoted highly osteogenic environments, with an osteogenic volume fraction > 95%. The integration of 3D-printed scaffolds transformed the single-implant constructs, enabling them to withstand 100% physiological load and increasing their osteogenic volume fraction to over 90%. Scaffolds also substantially reduced stress on the primary implants in all configurations. The plate and nail fixation augmented with a scaffold emerged as the most robust strategy, reducing conventional implant stresses to approximately 140 MPa while maintaining an exceptional osteogenic volume fraction > 99%. These findings highlight the quantitative potential of 3D-printed scaffolds to improve treatment outcomes for large bone defects.

Journal of Biomedical Materials Research Part B Applied BiomaterialsVol. 113(12)
National Technical University of Athens (GR), National and Kapodistrian University of Athens (GR), KAT General Hospital of Attica (GR)
Openalex Percentile: Top 10%
Orthopaedic implants and arthroplasty
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.