Low-cost particulate matter (PM) sensors are widely deployed for air quality monitoring, but their accuracy varies significantly with aerosol properties and environmental conditions. This study presents a systematic intercomparison of two commercially available low-cost optical particle sensors viz., OPC-N3 and PMS5003 across a matrix of temperature and RH conditions in a calibration chamber. The calibration chamber provided stable and reproducible conditions with uniform flow, validated using CFD simulations. We evaluated the sensor-reported size-resolved particle number concentrations and their cumulative distributions to four aerosols with varied physicochemical properties, including PSL (inert, nonhygroscopic), NaCl and (NH4)2SO4 (inorganic, hygroscopic), and soot (organic, nonhygroscopic) aerosols under four distinct RH and temperature conditions. The results indicate that PMS5003 showed negligible sensitivity to aerosol type, concentration, or environmental conditions, suggesting that its number concentration response depends largely on its restricted side-scatter geometry and internal transfer functions. Its agreement with the reference monitor was relatively better for cumulative fractions dominated by submicron particles (PM1). In contrast, OPC-N3 exhibited higher size-resolving capability with improved accuracy in the submicron range for nonabsorbing aerosols under high RH conditions. However, substantial deviations were observed for soot (errors > −400%) due to low scattering, coincidence and agglomeration effects. These findings highlight the importance of aerosol-specific assessment and correction strategies for reliable LCS measurements.

Authors

Institutions

Publication Details

Journal
ACS ES&T Air
Published
2025-12-11
DOI
https://doi.org/10.1021/acsestair.5c00262
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Evaluation of a Calibration Chamber for Low-Cost PM Sensors–Part 1: Number Concentration-Based Assessment

Manoranjan Sahu, Vasudev Malyan
ACS ES&T Air
Air Quality Monitoring and Forecasting
article

Design and Evaluation of a Calibration Chamber for Low-Cost PM Sensors–Part 1: Number Concentration-Based Assessment

Manoranjan Sahu, Vasudev Malyan
article en

Abstract

Low-cost particulate matter (PM) sensors are widely deployed for air quality monitoring, but their accuracy varies significantly with aerosol properties and environmental conditions. This study presents a systematic intercomparison of two commercially available low-cost optical particle sensors viz., OPC-N3 and PMS5003 across a matrix of temperature and RH conditions in a calibration chamber. The calibration chamber provided stable and reproducible conditions with uniform flow, validated using CFD simulations. We evaluated the sensor-reported size-resolved particle number concentrations and their cumulative distributions to four aerosols with varied physicochemical properties, including PSL (inert, nonhygroscopic), NaCl and (NH4)2SO4 (inorganic, hygroscopic), and soot (organic, nonhygroscopic) aerosols under four distinct RH and temperature conditions. The results indicate that PMS5003 showed negligible sensitivity to aerosol type, concentration, or environmental conditions, suggesting that its number concentration response depends largely on its restricted side-scatter geometry and internal transfer functions. Its agreement with the reference monitor was relatively better for cumulative fractions dominated by submicron particles (PM1). In contrast, OPC-N3 exhibited higher size-resolving capability with improved accuracy in the submicron range for nonabsorbing aerosols under high RH conditions. However, substantial deviations were observed for soot (errors > −400%) due to low scattering, coincidence and agglomeration effects. These findings highlight the importance of aerosol-specific assessment and correction strategies for reliable LCS measurements.

ACS ES&T AirVol. 3(1)
Indian Institute of Technology Bombay (IN), Machine Intelligence Research Institute (US), Nanoparticle BioChem (United States) (US)
Openalex Percentile: Top 62%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.