Evaluation of heat extraction using compact shallow ground heat panels with the interaction of stormwater- a residential case study

• Full-scale demonstration of a compact shallow GSHP integrated with stormwater infiltration. • Analytical model developed for heat gain in compact parallel ground heat panels. • Rainwater infiltration enhanced soil thermal conductivity and heat extraction efficiency. • Model reproduced measured coolant temperatures with ≤ 1.16 °C deviation at most points. • Non-uniform flow in parallel pipes revealed hydraulic imbalance and thermal interference. A bespoke parallel shallow horizontal Ground Source Heat Pump system (GSHP) with a small footprint (50 m 2 ) was installed to provide space heating and domestic hot water for a residential house in the North of England. The shallow GSHP was combined with a storm water infiltration trench and both were installed with an adjacent control house which was fitted with a standard gas boiler for space heating and hot water. Up to 350 metres of High Density Polyethylene (HDPE) pipe with an external diameter of 40 mm connected in 2 parallel compact panels was used at the front and back of the house with the GSHP. The paper aims to (i) present data for the response of the ground to heat extraction using shallow ground heat panels and (ii) analytically model the heat gain in the ground heat exchanger panel, accounting for the thermal resistivity between the heat exchanger pipes and the surrounding soil, as well as the varriations in ground temperature and thermal conductivity. Internal and external ambient air temperatures, rainfall, coolant flow rate, coolant temperature, ground temperature and ground water level were monitored for a full year. The comprehensive field data were analysed to demonstrate the ground response and evaluate the performance of the shallow parallel ground heat extraction panels. Field data indicated that rainwater enhanced heat extraction and caused temporary increase in the ground temperature. Results from the analytical model are compared with measured temperature at five points on the ground heat extraction panel. The model showed good levels of predictive performance of the coolant temperature along the ground panel. However, it was noted that the model overestimates the coolant temperature at the centre point of the ground panel.

Authors

Institutions

Publication Details

Journal
Geothermics
Published
2025-12-12
DOI
https://doi.org/10.1016/j.geothermics.2025.103563
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of heat extraction using compact shallow ground heat panels with the interaction of stormwater- a residential case study

Simon Tait, Alma Schellart, Mohamad Abdel-Aal, Omar Elkezza et al.
Geothermics
Geothermal Energy Systems and Applications
article

Evaluation of heat extraction using compact shallow ground heat panels with the interaction of stormwater- a residential case study

Simon Tait, Alma Schellart, Mohamad Abdel-Aal, Omar Elkezza, Mostafa Mohamed, Akbar Hanif Dawam Abdullah
article en

Abstract

• Full-scale demonstration of a compact shallow GSHP integrated with stormwater infiltration. • Analytical model developed for heat gain in compact parallel ground heat panels. • Rainwater infiltration enhanced soil thermal conductivity and heat extraction efficiency. • Model reproduced measured coolant temperatures with ≤ 1.16 °C deviation at most points. • Non-uniform flow in parallel pipes revealed hydraulic imbalance and thermal interference. A bespoke parallel shallow horizontal Ground Source Heat Pump system (GSHP) with a small footprint (50 m 2 ) was installed to provide space heating and domestic hot water for a residential house in the North of England. The shallow GSHP was combined with a storm water infiltration trench and both were installed with an adjacent control house which was fitted with a standard gas boiler for space heating and hot water. Up to 350 metres of High Density Polyethylene (HDPE) pipe with an external diameter of 40 mm connected in 2 parallel compact panels was used at the front and back of the house with the GSHP. The paper aims to (i) present data for the response of the ground to heat extraction using shallow ground heat panels and (ii) analytically model the heat gain in the ground heat exchanger panel, accounting for the thermal resistivity between the heat exchanger pipes and the surrounding soil, as well as the varriations in ground temperature and thermal conductivity. Internal and external ambient air temperatures, rainfall, coolant flow rate, coolant temperature, ground temperature and ground water level were monitored for a full year. The comprehensive field data were analysed to demonstrate the ground response and evaluate the performance of the shallow parallel ground heat extraction panels. Field data indicated that rainwater enhanced heat extraction and caused temporary increase in the ground temperature. Results from the analytical model are compared with measured temperature at five points on the ground heat extraction panel. The model showed good levels of predictive performance of the coolant temperature along the ground panel. However, it was noted that the model overestimates the coolant temperature at the centre point of the ground panel.

GeothermicsVol. 136
University of Bradford (GB), University of Exeter (GB), University of Sheffield (GB)
Openalex Percentile: Top 71%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.