Benefit of long-wave infrared camera in the measurement of respiratory rate: A pilot study

This study evaluated the accuracy of a long-wave infrared camera-based nostril temperature flow method for estimating respiratory rate across different breathing patterns. Five participants (four males and one female; aged between their mid-20s and mid-40s) were monitored using five sensors: a long-wave infrared camera, red-green-blue webcam, red-green-blue camera, respiratory belt, and electrocardiogram sensor. Participants performed regular (17-19 breaths per minute), shallow (32-98 breaths per minute), and deep (5-8 breaths per minute) breathing. The long-wave infrared camera demonstrated the highest accuracy among all devices, with mean absolute errors of 0.6 (regular), 2.4 (shallow), and 0 (deep) breaths per minute. The respiratory belt demonstrated similar performance for regular (0.2 breaths per minute) and deep (0 breaths per minute) breathing; however, it exhibited a significantly higher error (26.0 breaths per minute) during shallow breathing. In contrast, the red-green-blue webcam, red-green-blue camera, and electrocardiogram sensor produced higher mean absolute errors during shallow breathing (44.4, 32.4, and 34.2 breaths per minute, respectively). Overall, the long-wave infrared camera consistently outperformed the other modalities across all breathing patterns, particularly excelling in scenarios with extreme respiratory rates. These findings highlight the long-wave infrared camera's potential for accurate, noncontact respiratory rate monitoring in clinical and remote health settings, particularly where conventional sensors may fail due to motion artifacts or irregular breathing.

Authors

Institutions

Publication Details

Journal
Journal of International Medical Research
Published
2025-12-01
DOI
https://doi.org/10.1177/03000605251404229
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Benefit of long-wave infrared camera in the measurement of respiratory rate: A pilot study

J.H. Kim, Sungho Kim, Min Cheol Chang, Uday Debnath et al.
Journal of International Medical Research
Non-Invasive Vital Sign Monitoring
article

Benefit of long-wave infrared camera in the measurement of respiratory rate: A pilot study

J.H. Kim, Sungho Kim, Min Cheol Chang, Uday Debnath, Sreya Deb Srestha
article en

Abstract

This study evaluated the accuracy of a long-wave infrared camera-based nostril temperature flow method for estimating respiratory rate across different breathing patterns. Five participants (four males and one female; aged between their mid-20s and mid-40s) were monitored using five sensors: a long-wave infrared camera, red-green-blue webcam, red-green-blue camera, respiratory belt, and electrocardiogram sensor. Participants performed regular (17-19 breaths per minute), shallow (32-98 breaths per minute), and deep (5-8 breaths per minute) breathing. The long-wave infrared camera demonstrated the highest accuracy among all devices, with mean absolute errors of 0.6 (regular), 2.4 (shallow), and 0 (deep) breaths per minute. The respiratory belt demonstrated similar performance for regular (0.2 breaths per minute) and deep (0 breaths per minute) breathing; however, it exhibited a significantly higher error (26.0 breaths per minute) during shallow breathing. In contrast, the red-green-blue webcam, red-green-blue camera, and electrocardiogram sensor produced higher mean absolute errors during shallow breathing (44.4, 32.4, and 34.2 breaths per minute, respectively). Overall, the long-wave infrared camera consistently outperformed the other modalities across all breathing patterns, particularly excelling in scenarios with extreme respiratory rates. These findings highlight the long-wave infrared camera's potential for accurate, noncontact respiratory rate monitoring in clinical and remote health settings, particularly where conventional sensors may fail due to motion artifacts or irregular breathing.

Journal of International Medical ResearchVol. 53(12)
Yeungnam University (KR)
Openalex Percentile: Top 61%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Benefit of long-wave infrared camera in the measurement of respiratory rate: A pilot study — J.H. Kim, Sungho Kim, et al. · Journal of International Medical Research (2025) | TGRS Research Map | TGRS