Clinically Generalizable Low-Dose CT Denoising for Pediatric Imaging via Enhanced Diffusion Posterior Sampling

In total-body positron emission tomography and computed tomography (PET/CT) imaging, reducing the radiation dose of diagnostic CT scans is essential for minimizing overall radiation exposure, particularly in pediatric patients. Although deep learning-based denoising methods have shown promise in restoring low-dose CT (LDCT) to normal-dose CT (NDCT) quality, most approaches rely on structurally aligned paired data, which are difficult to acquire in clinical practice. Models trained on synthetic pairs often exhibit limited generalizability to real LDCT data. Unconditional diffusion models demonstrate outstanding generalizability, but fail to preserve structural fidelity. To address these challenges, we propose an enhanced diffusion posterior sampling (E-DPS) framework that combines a one-step denoiser U-Net with an unconditional diffusion model. Specifically, the U-Net estimator, trained on simulated LDCT-NDCT pairs, provides preliminary denoised outputs as structural constraints, whereas the diffusion model captures the prior distribution of NDCT images to enhance realism and generalizability. During inference, the U-Net predictions are integrated as constraints with tunable weights, thereby guiding diffusion posterior sampling. In addition, an intermediate-stage initialization strategy is introduced, significantly reducing the number of required sampling steps. Extensive experiments on simulated LDCT datasets across three dose levels demonstrate the superiority of our method, yielding average PSNR gains of +5.2% and +4.3% at unseen dose levels compared with state-of-the-art approaches. Moreover, on real LDCT images, E-DPS exhibits strong zero-shot generalizability, achieving better noise suppression while preserving anatomical detail. These results highlight the robustness and clinical potential of E-DPS for LDCT denoising.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-01-01
DOI
https://doi.org/10.1109/jbhi.2025.3642922
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinically Generalizable Low-Dose CT Denoising for Pediatric Imaging via Enhanced Diffusion Posterior Sampling

Hairong Zheng, Zhaoting Cheng, Hongmei Tang, Qianhao Chen et al.
IEEE Journal of Biomedical and Health Informatics
Medical Imaging Techniques and Applications
article

Clinically Generalizable Low-Dose CT Denoising for Pediatric Imaging via Enhanced Diffusion Posterior Sampling

Hairong Zheng, Zhaoting Cheng, Hongmei Tang, Qianhao Chen, Qiyang Zhang, Yang Wu, Xiaohua Zhu, Na Zhang, Shuang Song, Dong Liang, Zhanli Hu
article en

Abstract

In total-body positron emission tomography and computed tomography (PET/CT) imaging, reducing the radiation dose of diagnostic CT scans is essential for minimizing overall radiation exposure, particularly in pediatric patients. Although deep learning-based denoising methods have shown promise in restoring low-dose CT (LDCT) to normal-dose CT (NDCT) quality, most approaches rely on structurally aligned paired data, which are difficult to acquire in clinical practice. Models trained on synthetic pairs often exhibit limited generalizability to real LDCT data. Unconditional diffusion models demonstrate outstanding generalizability, but fail to preserve structural fidelity. To address these challenges, we propose an enhanced diffusion posterior sampling (E-DPS) framework that combines a one-step denoiser U-Net with an unconditional diffusion model. Specifically, the U-Net estimator, trained on simulated LDCT-NDCT pairs, provides preliminary denoised outputs as structural constraints, whereas the diffusion model captures the prior distribution of NDCT images to enhance realism and generalizability. During inference, the U-Net predictions are integrated as constraints with tunable weights, thereby guiding diffusion posterior sampling. In addition, an intermediate-stage initialization strategy is introduced, significantly reducing the number of required sampling steps. Extensive experiments on simulated LDCT datasets across three dose levels demonstrate the superiority of our method, yielding average PSNR gains of +5.2% and +4.3% at unseen dose levels compared with state-of-the-art approaches. Moreover, on real LDCT images, E-DPS exhibits strong zero-shot generalizability, achieving better noise suppression while preserving anatomical detail. These results highlight the robustness and clinical potential of E-DPS for LDCT denoising.

IEEE Journal of Biomedical and Health InformaticsVol. PP
Chinese Academy of Sciences (CN), Shenzhen Institutes of Advanced Technology (CN), Tongji Hospital (CN), Huazhong University of Science and Technology (CN)
Openalex Percentile: Top 45%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.