S3117 Accuracy of AI-Based Raman Spectroscopy in the Diagnosis of Gastric Cancer: A Systematic Review and Meta-Analysis

Introduction: Gastric cancer (GC) is a major global health burden, largely due to late-stage diagnosis. While endoscopy is the gold standard, it is invasive and may miss early lesions. Raman spectroscopy (RS), a technique detecting molecular vibrations, combined with artificial intelligence (AI), offers a rapid, minimally invasive alternative. This systematic review and meta-analysis assessed the diagnostic performance of AI-assisted RS for GC detection. Methods: Following PRISMA-DTA guidelines, 5 databases (PubMed, Web of Science, Scopus, VHL, and Google Scholar) were searched until February 2025. Eligible studies assessed AI-based RS for GC diagnosis and provided data for 2 × 2 contingency tables. Study quality was assessed with Quality Assessment of Diagnostic Accuracy Studies, version 2. Pooled sensitivity, specificity, likelihood ratios, diagnostic odds ratio, and area under the curve (AUC) were calculated using R. Heterogeneity, publication bias, and subgroup analyses (sample type, RS technique, AI model) were evaluated. Results: Nineteen studies (1,932 patients; 18,987 spectra) were included. Study quality was moderate-to-high, though risks of bias were noted in patient selection and index tests. Per-spectrum analysis (12 studies) showed pooled sensitivity of 94.6% (95% confidence interval [CI] 87.9-97.6%), specificity of 96.7% (95% CI 89.6-99.0%), and AUC of 0.967. Per-patient analysis (7 studies) reported sensitivity of 92.9% (95% CI 85.7-96.6%), specificity of 93.7% (95% CI 90.6-95.9%), and AUC of 0.964. Conventional RS performed best (P < 0.05). No significant differences were found by sample type (P = 0.1581) or AI model (P > 0.05). Egger’s test indicated possible publication bias (P < 0.05). Conclusion: AI-assisted RS shows high diagnostic accuracy for GC across sample types and models. Conventional RS performed best. These findings support its potential as a noninvasive diagnostic aid. Future research with standardized protocols and larger cohorts is needed to confirm clinical utility and reduce heterogeneity.

Authors

Publication Details

Journal
The American Journal of Gastroenterology
Published
2025-10-01
DOI
https://doi.org/10.14309/01.ajg.0001139928.57620.10
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

S3117 Accuracy of AI-Based Raman Spectroscopy in the Diagnosis of Gastric Cancer: A Systematic Review and Meta-Analysis

Mohammed Abu‐Rumaileh, Muhammed Elhadi, Asif Halimi, Bisher Sawaf et al.
The American Journal of Gastroenterology
Spectroscopy Techniques in Biomedical and Chemical Research
article

S3117 Accuracy of AI-Based Raman Spectroscopy in the Diagnosis of Gastric Cancer: A Systematic Review and Meta-Analysis

Mohammed Abu‐Rumaileh, Muhammed Elhadi, Asif Halimi, Bisher Sawaf, Sana Rabeeah
article en

Abstract

Introduction: Gastric cancer (GC) is a major global health burden, largely due to late-stage diagnosis. While endoscopy is the gold standard, it is invasive and may miss early lesions. Raman spectroscopy (RS), a technique detecting molecular vibrations, combined with artificial intelligence (AI), offers a rapid, minimally invasive alternative. This systematic review and meta-analysis assessed the diagnostic performance of AI-assisted RS for GC detection. Methods: Following PRISMA-DTA guidelines, 5 databases (PubMed, Web of Science, Scopus, VHL, and Google Scholar) were searched until February 2025. Eligible studies assessed AI-based RS for GC diagnosis and provided data for 2 × 2 contingency tables. Study quality was assessed with Quality Assessment of Diagnostic Accuracy Studies, version 2. Pooled sensitivity, specificity, likelihood ratios, diagnostic odds ratio, and area under the curve (AUC) were calculated using R. Heterogeneity, publication bias, and subgroup analyses (sample type, RS technique, AI model) were evaluated. Results: Nineteen studies (1,932 patients; 18,987 spectra) were included. Study quality was moderate-to-high, though risks of bias were noted in patient selection and index tests. Per-spectrum analysis (12 studies) showed pooled sensitivity of 94.6% (95% confidence interval [CI] 87.9-97.6%), specificity of 96.7% (95% CI 89.6-99.0%), and AUC of 0.967. Per-patient analysis (7 studies) reported sensitivity of 92.9% (95% CI 85.7-96.6%), specificity of 93.7% (95% CI 90.6-95.9%), and AUC of 0.964. Conventional RS performed best (P < 0.05). No significant differences were found by sample type (P = 0.1581) or AI model (P > 0.05). Egger’s test indicated possible publication bias (P < 0.05). Conclusion: AI-assisted RS shows high diagnostic accuracy for GC across sample types and models. Conventional RS performed best. These findings support its potential as a noninvasive diagnostic aid. Future research with standardized protocols and larger cohorts is needed to confirm clinical utility and reduce heterogeneity.

The American Journal of GastroenterologyVol. 120(10S2)
Openalex Percentile: Top 73%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.