S6490 Reducing Radiation and Intervention: The Role of Point-of-Care Ultrasound in Tracking Gastrointestinal Foreign Bodies

Introduction: In adults, foreign body ingestion is often associated with psychiatric disorders, incarceration, or intellectual disabilities, with intentional ingestion being especially prevalent in prison populations. While most ingested objects pass spontaneously, 10%–20% requires endoscopic intervention, and less than 1% necessitates surgical procedures. Plain radiographs have been the primary diagnostic tool, providing information on the location, size, shape, and number of ingested foreign bodies, and helping to exclude aspiration. However, radiolucent materials, such as chicken bones and thin metal objects are often not visible on x-rays. Ultrasound has not been incorporated into standard diagnostic guidelines, and there remains a paucity of literature supporting its routine use in the evaluation of gastrointestinal foreign body ingestion. Case Description/Methods: A 25-year-old man from a corrections facility with a history of psychiatric disorder, specifically antisocial personality disorder, presented to the emergency department after ingesting a foreign body, a screw. The patient reported swallowing the screw impulsively in an attempt to be removed from confinement. He was asymptomatic upon arrival and had a normal physical exam. A kidney, ureter, and bladder (KUB) scan identified a flat-tip screw, measuring 22 mm × 13 mm, located in the distal stomach. A gastroenterology consultation was obtained, and it was recommended that the patient remain nil per os (NPO) with daily KUB scans to monitor the screw’s progression. Since the screw was less than 2.5 cm in size, endoscopic removal was not necessary. Discussion: This case aims to determine the effectiveness of point-of-care ultrasound (POCUS) in managing gastrointestinal (GI) foreign body ingestion, particularly in populations at higher risk. Repeated imaging to monitor the progression of a foreign body often results in increased radiation exposure and may cause patient discomfort, especially in cases requiring serial assessments. The use of POCUS within the GI system remains underexplored. The foreign body consistently appeared as a hyperechoic linear structure on POCUS, allowing for real-time visualization at every stage transit. The ability to perform serial bedside ultrasounds provided a non-invasive, radiation-free means of tracking the foreign body, offering advantages in patient safety. Furthermore, the cost-effectiveness and ease of access associated with POCUS make it a valuable tool when rapid decision-making is required, such as emergency departments and correctional facilities.

Authors

Publication Details

Journal
The American Journal of Gastroenterology
Published
2025-10-01
DOI
https://doi.org/10.14309/01.ajg.0001154420.52819.62
Primary Topic
Foreign Body Medical Cases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

S6490 Reducing Radiation and Intervention: The Role of Point-of-Care Ultrasound in Tracking Gastrointestinal Foreign Bodies

Guillermo Izquierdo-Pretel, Juan Mantilla, Mehak Sharma, Carolina Valdes-Guicciardi
The American Journal of Gastroenterology
Foreign Body Medical Cases
article

S6490 Reducing Radiation and Intervention: The Role of Point-of-Care Ultrasound in Tracking Gastrointestinal Foreign Bodies

Guillermo Izquierdo-Pretel, Juan Mantilla, Mehak Sharma, Carolina Valdes-Guicciardi
article en

Abstract

Introduction: In adults, foreign body ingestion is often associated with psychiatric disorders, incarceration, or intellectual disabilities, with intentional ingestion being especially prevalent in prison populations. While most ingested objects pass spontaneously, 10%–20% requires endoscopic intervention, and less than 1% necessitates surgical procedures. Plain radiographs have been the primary diagnostic tool, providing information on the location, size, shape, and number of ingested foreign bodies, and helping to exclude aspiration. However, radiolucent materials, such as chicken bones and thin metal objects are often not visible on x-rays. Ultrasound has not been incorporated into standard diagnostic guidelines, and there remains a paucity of literature supporting its routine use in the evaluation of gastrointestinal foreign body ingestion. Case Description/Methods: A 25-year-old man from a corrections facility with a history of psychiatric disorder, specifically antisocial personality disorder, presented to the emergency department after ingesting a foreign body, a screw. The patient reported swallowing the screw impulsively in an attempt to be removed from confinement. He was asymptomatic upon arrival and had a normal physical exam. A kidney, ureter, and bladder (KUB) scan identified a flat-tip screw, measuring 22 mm × 13 mm, located in the distal stomach. A gastroenterology consultation was obtained, and it was recommended that the patient remain nil per os (NPO) with daily KUB scans to monitor the screw’s progression. Since the screw was less than 2.5 cm in size, endoscopic removal was not necessary. Discussion: This case aims to determine the effectiveness of point-of-care ultrasound (POCUS) in managing gastrointestinal (GI) foreign body ingestion, particularly in populations at higher risk. Repeated imaging to monitor the progression of a foreign body often results in increased radiation exposure and may cause patient discomfort, especially in cases requiring serial assessments. The use of POCUS within the GI system remains underexplored. The foreign body consistently appeared as a hyperechoic linear structure on POCUS, allowing for real-time visualization at every stage transit. The ability to perform serial bedside ultrasounds provided a non-invasive, radiation-free means of tracking the foreign body, offering advantages in patient safety. Furthermore, the cost-effectiveness and ease of access associated with POCUS make it a valuable tool when rapid decision-making is required, such as emergency departments and correctional facilities.

The American Journal of GastroenterologyVol. 120(10S2)
Openalex Percentile: Top 45%
Foreign Body Medical Cases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.