Enhanced wear resistance of TiBw/Ti-6Al-4V induced by ultrasonic peening

A discontinuously reinforced titanium matrix composite was fabricated using laser solid forming and subsequently subjected to ultrasonic peening (USP). USP treatment resulted in pronounced grain refinement of the Ti-6Al-4V matrix, accompanied by substantial increases in compressive residual stress (CRS) and microhardness. With increasing USP duration, αTi grains were refined to the nanoscale, primarily driven by dislocation motion. The maximum CRS and microhardness of specimens peened for 8, 16, and 32 min were −921.9 MPa and 594.5 HV 0.025 , −1063.8 MPa and 631.8 HV 0.025 , −1175.4 MPa and 689.3 HV 0.025 , respectively. Moreover, compared to the untreated sample, the wear volumes of specimens peened for 8, 16, and 32 min decreased by 11.6%, 25.6%, and 32.9%, respectively. Abrasive wear remained the dominant wear mechanism.

Authors

Institutions

Publication Details

Journal
Materials Science and Technology
Published
2025-12-11
DOI
https://doi.org/10.1177/02670836251406912
Primary Topic
Surface Treatment and Residual Stress
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced wear resistance of TiBw/Ti-6Al-4V induced by ultrasonic peening

Xuehong Shen, Dong Han, Yanying Guan, Qi Zhang et al.
Materials Science and Technology
Surface Treatment and Residual Stress
article

Enhanced wear resistance of TiBw/Ti-6Al-4V induced by ultrasonic peening

Xuehong Shen, Dong Han, Yanying Guan, Qi Zhang, Deng Pan, Xianjie Zhang
article en

Abstract

A discontinuously reinforced titanium matrix composite was fabricated using laser solid forming and subsequently subjected to ultrasonic peening (USP). USP treatment resulted in pronounced grain refinement of the Ti-6Al-4V matrix, accompanied by substantial increases in compressive residual stress (CRS) and microhardness. With increasing USP duration, αTi grains were refined to the nanoscale, primarily driven by dislocation motion. The maximum CRS and microhardness of specimens peened for 8, 16, and 32 min were −921.9 MPa and 594.5 HV 0.025 , −1063.8 MPa and 631.8 HV 0.025 , −1175.4 MPa and 689.3 HV 0.025 , respectively. Moreover, compared to the untreated sample, the wear volumes of specimens peened for 8, 16, and 32 min decreased by 11.6%, 25.6%, and 32.9%, respectively. Abrasive wear remained the dominant wear mechanism.

Materials Science and Technology
Northwestern Polytechnical University (CN), Craft Group (China) (CN)
Openalex Percentile: Top 59%
Surface Treatment and Residual Stress
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.