Non-Fullerene Organic Semiconductor ITIC as a Redox Mediator in Electrochemical Glucose Biosensors

ITIC's superior electron-accepting capacity and efficient oxygen reduction motivated the design of a sensor to enhance sensitivity, selectivity, and stability over conventional oxygen-dependent or fullerene-based systems. As oxygen acts as the terminal reagent in enzymatic glucose oxidation, we developed an ITIC-mediated glucose oxidase (GOx) biosensor on glassy carbon (GCE) and screen-printed carbon electrodes (SPCE). ITIC, a non-fullerene organic semiconductor, was drop-cast onto the electrode to catalyze oxygen reduction, followed by GOx immobilization in a chitosan matrix. Scanning electron microscopy (SEM) confirmed uniform, ultrathin coatings without significant morphological changes upon ITIC and GOx deposition. Electrochemical studies (cyclic (CV) and differential pulse voltammetry (DPV)) revealed a distinct ITIC reduction peak at -0.7 V (vs. Ag/AgCl) and a glucose-dependent current decrease, consistent with mediated electron transfer during enzymatic oxidation. Under optimized conditions, the GCE-based biosensor showed a sensitivity of 10.7 μA L mmol<sup>-1</sup>, a linear dynamic range (LDR) of 0.10-1.00 mmol L<sup>-1</sup>, and detection (LOD)/quantification (LOQ) limits of 0.02 and 0.06 mmol L<sup>-1</sup>, respectively. The SPCE device displayed sensitivity (3.8 μA L mmol<sup>-1</sup>) and maintained excellent linearity (R<sup>2</sup> > 0.99) with LOD and LOQ of 0.05 and 0.16 mmol L<sup>-1</sup>. Both platforms showed good precision (RSD < 5%) and reliable recovery in deproteinized plasma and artificial tears (90-104%). The superior performance of the GCE is attributed to higher ITIC loading, faster electron transfer, and reduced background current, while the SPCE offers a low-cost, disposable format with sufficient analytical performance for point-of-care glucose monitoring.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-12-11
DOI
https://doi.org/10.3390/s25247535
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Fullerene Organic Semiconductor ITIC as a Redox Mediator in Electrochemical Glucose Biosensors

Luiz H. Marcolino‐Júnior, Leni Akcelrud, Márcio F. Bergamini, Maurício A.P. Papi et al.
Sensors
Electrochemical sensors and biosensors
article

Non-Fullerene Organic Semiconductor ITIC as a Redox Mediator in Electrochemical Glucose Biosensors

Luiz H. Marcolino‐Júnior, Leni Akcelrud, Márcio F. Bergamini, Maurício A.P. Papi, Sandra de Melo Cassemiro, Victor G. Scheidweiler
article en

Abstract

ITIC's superior electron-accepting capacity and efficient oxygen reduction motivated the design of a sensor to enhance sensitivity, selectivity, and stability over conventional oxygen-dependent or fullerene-based systems. As oxygen acts as the terminal reagent in enzymatic glucose oxidation, we developed an ITIC-mediated glucose oxidase (GOx) biosensor on glassy carbon (GCE) and screen-printed carbon electrodes (SPCE). ITIC, a non-fullerene organic semiconductor, was drop-cast onto the electrode to catalyze oxygen reduction, followed by GOx immobilization in a chitosan matrix. Scanning electron microscopy (SEM) confirmed uniform, ultrathin coatings without significant morphological changes upon ITIC and GOx deposition. Electrochemical studies (cyclic (CV) and differential pulse voltammetry (DPV)) revealed a distinct ITIC reduction peak at -0.7 V (vs. Ag/AgCl) and a glucose-dependent current decrease, consistent with mediated electron transfer during enzymatic oxidation. Under optimized conditions, the GCE-based biosensor showed a sensitivity of 10.7 μA L mmol<sup>-1</sup>, a linear dynamic range (LDR) of 0.10-1.00 mmol L<sup>-1</sup>, and detection (LOD)/quantification (LOQ) limits of 0.02 and 0.06 mmol L<sup>-1</sup>, respectively. The SPCE device displayed sensitivity (3.8 μA L mmol<sup>-1</sup>) and maintained excellent linearity (R<sup>2</sup> > 0.99) with LOD and LOQ of 0.05 and 0.16 mmol L<sup>-1</sup>. Both platforms showed good precision (RSD < 5%) and reliable recovery in deproteinized plasma and artificial tears (90-104%). The superior performance of the GCE is attributed to higher ITIC loading, faster electron transfer, and reduced background current, while the SPCE offers a low-cost, disposable format with sufficient analytical performance for point-of-care glucose monitoring.

SensorsVol. 25(24)
Universidade Federal do Paraná (BR)
Openalex Percentile: Top 60%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.