Automated annular suture device versus conventional annular suture technique in endoscopic aortic valve replacement: A propensity score–matched analysis

The use of the RAM device in endoscopic aortic valve replacement is as safe, feasible, and effective as the conventional annular suture technique and yields excellent early outcomes. After a short learning curve, the RAM device was associated with reduced surgical time by facilitating annular suturing in endoscopic fashion.

Authors

Institutions

Publication Details

Journal
JTCVS Techniques
Published
2025-10-15
DOI
https://doi.org/10.1016/j.xjtc.2025.09.034
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated annular suture device versus conventional annular suture technique in endoscopic aortic valve replacement: A propensity score–matched analysis

Farhad Bakhtiary, Ali Ahmad, Miriam Silaschi, Ali Bayram et al.
JTCVS Techniques
Cardiac Valve Diseases and Treatments
article

Automated annular suture device versus conventional annular suture technique in endoscopic aortic valve replacement: A propensity score–matched analysis

Farhad Bakhtiary, Ali Ahmad, Miriam Silaschi, Ali Bayram, Mirko Doss, Ömür Akhavuz, Saad Salamate, Mohamed Amer, Sami Sirat, Jacqueline Kruse
article en

Abstract

The use of the RAM device in endoscopic aortic valve replacement is as safe, feasible, and effective as the conventional annular suture technique and yields excellent early outcomes. After a short learning curve, the RAM device was associated with reduced surgical time by facilitating annular suturing in endoscopic fashion.

JTCVS TechniquesVol. 34
University Hospital Bonn (DE), Helios Hospital Siegburg (DE), Helios Universitätsklinikum Wuppertal (DE)
Openalex Percentile: Top 43%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Automated annular suture device versus conventional annular suture technique in endoscopic aortic valve replacement: A propensity score–matched analysis — Farhad Bakhtiary, Ali Ahmad, et al. · JTCVS Techniques (2025) | TGRS Research Map | TGRS