Evaluation of Patient Dose from Chest Ct Examinations in Selected Diagnostics Centres in Abuja, Nigeria

This study assessed patient radiation exposure from chest computed tomography (CT) examinations across three diagnostic centers (A, B, and C) in Abuja, Nigeria. A total of chest 60 CT scan records were retrospectively analyzed, and radiation dose parameters including weighted CT dose index (CTDIw), dose length product (DLP), and effective dose were evaluated. Technical factors such as tube current (mAs), tube voltage (kVp), pitch, and patient body weight were also collected to determine their influence on dose variations. The mean CTDIw values were 5.49, 5.88, and 7.42 mGy.cm for Centers A, B, and C, respectively, while the corresponding DLP values were 271.48 ± 183.2, 253.32 ± 120.4, and 437.16 ± 433.5 mGy·cm. Effective doses to the chest were 4.62, 4.31, and 7.43 mSv. Centers A and B demonstrated relatively optimized protocols, whereas Center C consistently reported higher radiation metrics. Technical and demographic data revealed higher mAs (220 ± 35), tube voltage (120 kVp), lower pitch (0.9), and higher mean body weight (78 ± 12 kg) in Center C compared with Centers A and B, accounting for its higher dose indices. Compared with international benchmarks, results from Centers A and B were consistent with European and Turkish diagnostic reference levels (DRLs), while Center C exceeded some international thresholds but remained within Nigerian DRL frameworks. These findings highlight the influence of patient and technical factors on dose variation and emphasize the need for protocol harmonization to optimize patient safety without compromising diagnostic quality.

Authors

Institutions

Publication Details

Journal
American Journal of Physics and Applications
Published
2025-12-09
DOI
https://doi.org/10.11648/j.ajpa.20251306.12
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Patient Dose from Chest Ct Examinations in Selected Diagnostics Centres in Abuja, Nigeria

Imad Mohammed, Ilupeju Yemisi, Odeleye Samson
American Journal of Physics and Applications
Radiation Dose and Imaging
article

Evaluation of Patient Dose from Chest Ct Examinations in Selected Diagnostics Centres in Abuja, Nigeria

Imad Mohammed, Ilupeju Yemisi, Odeleye Samson
article en

Abstract

This study assessed patient radiation exposure from chest computed tomography (CT) examinations across three diagnostic centers (A, B, and C) in Abuja, Nigeria. A total of chest 60 CT scan records were retrospectively analyzed, and radiation dose parameters including weighted CT dose index (CTDIw), dose length product (DLP), and effective dose were evaluated. Technical factors such as tube current (mAs), tube voltage (kVp), pitch, and patient body weight were also collected to determine their influence on dose variations. The mean CTDIw values were 5.49, 5.88, and 7.42 mGy.cm for Centers A, B, and C, respectively, while the corresponding DLP values were 271.48 ± 183.2, 253.32 ± 120.4, and 437.16 ± 433.5 mGy·cm. Effective doses to the chest were 4.62, 4.31, and 7.43 mSv. Centers A and B demonstrated relatively optimized protocols, whereas Center C consistently reported higher radiation metrics. Technical and demographic data revealed higher mAs (220 ± 35), tube voltage (120 kVp), lower pitch (0.9), and higher mean body weight (78 ± 12 kg) in Center C compared with Centers A and B, accounting for its higher dose indices. Compared with international benchmarks, results from Centers A and B were consistent with European and Turkish diagnostic reference levels (DRLs), while Center C exceeded some international thresholds but remained within Nigerian DRL frameworks. These findings highlight the influence of patient and technical factors on dose variation and emphasize the need for protocol harmonization to optimize patient safety without compromising diagnostic quality.

American Journal of Physics and ApplicationsVol. 13(6)
Nasarawa State University (NG), National Hospital Abuja (NG), University of Maiduguri (NG)
Openalex Percentile: Top 46%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.