S2231 Post Procedure Operational Efficiencies Associated With Single-Use Duodenoscopes Compared to Reusable Duodenoscopes: A Head-to-Head Case Series at a Regional Academic Medical Center

Introduction: From 2012 to 2016 reports were published on outbreaks caused by duodenoscope contamination. In 2020 the FDA published guidelines recommending Single-Use Duodenoscopes (SUD) or Reusable Duodenoscopes (RD) that incorporate disposable components. Prior studies have evaluated the operational burden of reprocessing RD. This study aims to quantify the time differences in post procedure handling of SUD versus RD and possible economic savings. Methods: This case series analyzed 60 ERCP procedures performed at a single center between June 2024 and November 2024. The decision to use SUD versus RD was made clinically without bias on a case-by-case basis in accordance with published guidelines. Post-ERCP observations included device turnover time (DT), room turnover time (RT), count of staff members handling the scope, and associated operations. Normal data was analyzed with ANOVA; non-normal data with Wilcoxon rank-sum. Economic valuation of differences in time observations was estimated with data from the Bureau of Labor Statistics. Results: The analysis included 29 SUD and 31 RD cases, comprising 59 ERCP and 1 ERCP + EUS procedure (an RD case). SUD required a median of 0 minutes DT versus 77 minutes for RD (mean difference, Δ = 77 minutes; Δ 95% CI: 69–84 minutes; P < 0.0001). SUD required a median RT of 15 minutes versus 21 minutes for RD (Δ = 6 minutes; Δ 95% CI: 1–9 minutes; P = 0.013). SUD required 1 fewer staff member versus RD (P < 0.001). The aggregate economic value of this operational time was estimated at approximately $700 for SUD versus $1000 for RD; Δ = $279 favorable to SUD (Δ 95% CI: $100–$470; P < 0.01). Conclusion: To our knowledge, head-to-head analysis of post procedure time savings comparing SUD and RD are currently lacking and this study provides the first evidence-based data available. SUD saved on average 77 minutes of staff time through eliminating RD reprocessing operations and on average of 6 minutes faster room turnover by saving time spent suctioning the working channel of the RD, cleaning the shaft, unplugging the buttons, storing in bins, and transporting to the scope room; estimates of the economic savings are upwards of $470. Possible case volume expansion enabled by improved room turnover may further extend these economic benefits. SUD have the potential to increase operational efficiencies and savings, which should be considered by economic value analysis teams evaluating their incorporation into clinical practice.

Authors

Publication Details

Journal
The American Journal of Gastroenterology
Published
2025-10-01
DOI
https://doi.org/10.14309/01.ajg.0001136384.94104.96
Primary Topic
Medical Device Sterilization and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

S2231 Post Procedure Operational Efficiencies Associated With Single-Use Duodenoscopes Compared to Reusable Duodenoscopes: A Head-to-Head Case Series at a Regional Academic Medical Center

Jonh J. Pineda Bonilla, Michael Reymundi, Michael Cangelosi
The American Journal of Gastroenterology
Medical Device Sterilization and Disinfection
article

S2231 Post Procedure Operational Efficiencies Associated With Single-Use Duodenoscopes Compared to Reusable Duodenoscopes: A Head-to-Head Case Series at a Regional Academic Medical Center

Jonh J. Pineda Bonilla, Michael Reymundi, Michael Cangelosi
article en

Abstract

Introduction: From 2012 to 2016 reports were published on outbreaks caused by duodenoscope contamination. In 2020 the FDA published guidelines recommending Single-Use Duodenoscopes (SUD) or Reusable Duodenoscopes (RD) that incorporate disposable components. Prior studies have evaluated the operational burden of reprocessing RD. This study aims to quantify the time differences in post procedure handling of SUD versus RD and possible economic savings. Methods: This case series analyzed 60 ERCP procedures performed at a single center between June 2024 and November 2024. The decision to use SUD versus RD was made clinically without bias on a case-by-case basis in accordance with published guidelines. Post-ERCP observations included device turnover time (DT), room turnover time (RT), count of staff members handling the scope, and associated operations. Normal data was analyzed with ANOVA; non-normal data with Wilcoxon rank-sum. Economic valuation of differences in time observations was estimated with data from the Bureau of Labor Statistics. Results: The analysis included 29 SUD and 31 RD cases, comprising 59 ERCP and 1 ERCP + EUS procedure (an RD case). SUD required a median of 0 minutes DT versus 77 minutes for RD (mean difference, Δ = 77 minutes; Δ 95% CI: 69–84 minutes; P < 0.0001). SUD required a median RT of 15 minutes versus 21 minutes for RD (Δ = 6 minutes; Δ 95% CI: 1–9 minutes; P = 0.013). SUD required 1 fewer staff member versus RD (P < 0.001). The aggregate economic value of this operational time was estimated at approximately $700 for SUD versus $1000 for RD; Δ = $279 favorable to SUD (Δ 95% CI: $100–$470; P < 0.01). Conclusion: To our knowledge, head-to-head analysis of post procedure time savings comparing SUD and RD are currently lacking and this study provides the first evidence-based data available. SUD saved on average 77 minutes of staff time through eliminating RD reprocessing operations and on average of 6 minutes faster room turnover by saving time spent suctioning the working channel of the RD, cleaning the shaft, unplugging the buttons, storing in bins, and transporting to the scope room; estimates of the economic savings are upwards of $470. Possible case volume expansion enabled by improved room turnover may further extend these economic benefits. SUD have the potential to increase operational efficiencies and savings, which should be considered by economic value analysis teams evaluating their incorporation into clinical practice.

The American Journal of GastroenterologyVol. 120(10S2)
Openalex Percentile: Top 62%
Medical Device Sterilization and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.