Constructing Method of an Ultrasonic System of Thermosonic Bonding Installation Using the Ball–Wedge Technique
The paper proposes a method of constructing an ultrasonic system that determines the stability of thermosonic microwelding of gold wire with a diameter of 17.5–50 µm when assembling electronic products in metal-ceramic enclosures. A simulation of waveguide was conducted at the standard frequency of ultrasonic oscillations of 66 kHz and an increased frequency of 136 kHz.
Authors
- I. B. Petuhov
- V. L. Lanin
Institutions
- Belarusian State University of Informatics and Radioelectronics (BY)
Publication Details
- Journal
- Surface Engineering and Applied Electrochemistry
- Published
- 2025-12-01
- DOI
- https://doi.org/10.3103/s1068375525700930
- Primary Topic
- Engineering and Materials Science Studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00