Taguchi Optimization of Additively Manufactured <scp>PEKK</scp> and Silicon Nitride Loaded <scp>PEKK</scp> for Medical Device Applications
Silicon nitride (Si<sub>3</sub>N<sub>4</sub>) is reported to exhibit antibacterial properties and support osteoblast maturation, while polyetherketoneketone (PEKK) is considered to potentially have antibacterial and osseointegrative properties while offering favorable manufacturability through extrusion-based additive manufacturing compared to traditional ceramics manufacturing. Incorporating silicon nitride into PEKK is hypothesized to enhance its bioactivity while maintaining processability, making Si<sub>3</sub>N<sub>4</sub>-PEKK composites promising for medical implants. Our objective was to determine optimal fused filament fabrication (FFF) parameters for PEKK and Si<sub>3</sub>N<sub>4</sub>-PEKK. Taguchi optimization (L9 array, n = 5) was performed on PEKK and 15 vol.% Si<sub>3</sub>N<sub>4</sub>-PEKK to assess the impact of printing parameters (layer height: 0.1, 0.2, and 0.3 mm; nozzle temperature (PEKK/Si<sub>3</sub>N<sub>4</sub>-PEKK): 340/380, 370/400, and 400/420; bed temperature: 130°C, 150°C, and 170°C; and chamber temperature: 110°C, 130°C, and 150°C) on ultimate tensile strength (UTS). Z-directional tensile specimens were printed on a medical FFF printer. Specimens underwent tensile testing according to ASTM D638. Signal/noise ratios for UTS were calculated and ANOVA (Minitab 21.4.2) was used to assess statistical significance (p < 0.05). Layer height had the greatest impact on UTS for both PEKK and Si<sub>3</sub>N<sub>4</sub>-PEKK. Optimal nozzle and chamber temperatures were 400°C and 130°C, respectively, while the optimal layer height was 0.1 mm for both materials. The optimal bed temperature for PEKK and Si<sub>3</sub>N<sub>4</sub>-PEKK was 150°C and 170°C, respectively. For PEKK, differences in all parameters were significant except for bed temperature, while for Si<sub>3</sub>N<sub>4</sub>-PEKK all parameters were significant except for nozzle temperature. The specimens with optimum statistically significant parameters showed the highest UTS for both PEKK (91 ± 2 MPa) and Si<sub>3</sub>N<sub>4</sub>-PEKK (76 ± 3 MPa). Layer height is the most influential printing variable for both PEKK and Si<sub>3</sub>N<sub>4</sub>-PEKK. The optimal PEKK printing condition has a comparable UTS, while Si<sub>3</sub>N<sub>4</sub>-PEKK achieved 84% of the injection-molded value for neat PEKK.
Authors
- Tabitha Derr (ORCID: https://orcid.org/0000-0003-0967-1006)
- Cemile Başgül (ORCID: https://orcid.org/0009-0004-9701-590X)
- Ryan M. Bock (ORCID: https://orcid.org/0000-0002-3422-7751)
- Paul M. DeSantis (ORCID: https://orcid.org/0000-0003-1535-6125)
- Steven M. Kurtz (ORCID: https://orcid.org/0000-0002-3885-500X)
Institutions
- SINTX Technologies (United States) (US)
- Drexel University (US)
Publication Details
- Journal
- Journal of Biomedical Materials Research Part B Applied Biomaterials
- Published
- 2025-12-01
- DOI
- https://doi.org/10.1002/jbmb.70009
- Primary Topic
- Additive Manufacturing and 3D Printing Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Institute of Dental and Craniofacial Research