Quantum Weak Force Sensor with Cross‐Kerr Nonlinearity and Parametric Amplification

ABSTRACT The sensitivity of optomechanical sensors is fundamentally constrained by the combined effects of shot noise and quantum back‐action. Here we show that the joint action of cross‐Kerr nonlinearity and an optical parametric amplifier (OPA) can effectively suppress these noises. By tailoring the cross‐Kerr strength, the force‐sensing sensitivity can surpass the standard quantum limit (SQL), while an optimal driving power broadens the detection bandwidth. We further find that the system becomes unstable when the detuning falls below . Importantly, the inclusion of an OPA enhances robustness against thermal fluctuations, allowing the sensitivity of force measurement to surpass the SQL even at temperatures up to 300 K. A detailed noise analysis reveals that cross‐Kerr nonlinearity predominantly suppresses back‐action noise, whereas the OPA provides a strong reduction of shot noise. These results establish a promising hybrid strategy for realizing optomechanical sensors that combine high sensitivity with thermal resilience, with broad applications ranging from medical diagnostics to gravitational‐wave astronomy.

Authors

Institutions

Publication Details

Journal
Advanced Quantum Technologies
Published
2025-12-09
DOI
https://doi.org/10.1002/qute.202500793
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantum Weak Force Sensor with Cross‐Kerr Nonlinearity and Parametric Amplification

Shou Zhang, Hong‐Fu Wang, Xue Han, Yingjian Zhu
Advanced Quantum Technologies
Mechanical and Optical Resonators
article

Quantum Weak Force Sensor with Cross‐Kerr Nonlinearity and Parametric Amplification

Shou Zhang, Hong‐Fu Wang, Xue Han, Yingjian Zhu
article en

Abstract

ABSTRACT The sensitivity of optomechanical sensors is fundamentally constrained by the combined effects of shot noise and quantum back‐action. Here we show that the joint action of cross‐Kerr nonlinearity and an optical parametric amplifier (OPA) can effectively suppress these noises. By tailoring the cross‐Kerr strength, the force‐sensing sensitivity can surpass the standard quantum limit (SQL), while an optimal driving power broadens the detection bandwidth. We further find that the system becomes unstable when the detuning falls below . Importantly, the inclusion of an OPA enhances robustness against thermal fluctuations, allowing the sensitivity of force measurement to surpass the SQL even at temperatures up to 300 K. A detailed noise analysis reveals that cross‐Kerr nonlinearity predominantly suppresses back‐action noise, whereas the OPA provides a strong reduction of shot noise. These results establish a promising hybrid strategy for realizing optomechanical sensors that combine high sensitivity with thermal resilience, with broad applications ranging from medical diagnostics to gravitational‐wave astronomy.

Advanced Quantum Technologies
Yanbian University of Science and Technology (CN), Yanbian University (CN)
Openalex Percentile: Top 69%
Mechanical and Optical Resonators
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.