Sequential scans of 18F-flutemetamol PET using PET/CT and PET/MRI: influence of amyloid burden, scan interval, and age

Visual interpretation showed high agreement between PET/CT and PET/MRI (κ = 0.97), and 98% concordance with CSF findings. SUVr and Centiloid scale demonstrated a strong intraclass correlation coefficient of 0.96-0.98. However, SUVr and Centiloid scale were significantly higher from PET/CT than from PET/MRI, except for SUVr using CGM. Age and Centiloid scale were significant predictors of modality differences. Scan interval was also significant when CGM was used as the reference region. Dynamic PET/MRI revealed time-dependent increases in Centiloid scale among amyloid-positive participants. High concordance in visual and quantitative assessments was seen for <sup>18</sup>F-flutemetamol PET/CT (90 min) and subsequent PET/MRI (120 min). While diagnostic agreement was preserved, quantitative values were influenced by amyloid burden, age, and scan timing. These findings suggest a need for careful consideration when interpreting quantitative metrics across different imaging modalities and time points.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Radiology
Published
2025-12-10
DOI
https://doi.org/10.1007/s11604-025-01915-1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sequential scans of 18F-flutemetamol PET using PET/CT and PET/MRI: influence of amyloid burden, scan interval, and age

Koji Itagaki, Takashi Hanakawa, K. Goto, Sachi Okuchi et al.
Japanese Journal of Radiology
Medical Imaging Techniques and Applications
article

Sequential scans of 18F-flutemetamol PET using PET/CT and PET/MRI: influence of amyloid burden, scan interval, and age

Koji Itagaki, Takashi Hanakawa, K. Goto, Sachi Okuchi, Akira Kuzuya, Manabu Kubota, Atsushi Shima, Satoshi Nakajima, Sakiho Ueda, Yuji Nakamoto, Yasutaka Fushimi, Katsuhiko Mitsumoto, Nobukatsu Sawamoto, Takayuki Yamamoto, Akihiko Sakata, Shin Morooka
article en

Abstract

Visual interpretation showed high agreement between PET/CT and PET/MRI (κ = 0.97), and 98% concordance with CSF findings. SUVr and Centiloid scale demonstrated a strong intraclass correlation coefficient of 0.96-0.98. However, SUVr and Centiloid scale were significantly higher from PET/CT than from PET/MRI, except for SUVr using CGM. Age and Centiloid scale were significant predictors of modality differences. Scan interval was also significant when CGM was used as the reference region. Dynamic PET/MRI revealed time-dependent increases in Centiloid scale among amyloid-positive participants. High concordance in visual and quantitative assessments was seen for <sup>18</sup>F-flutemetamol PET/CT (90 min) and subsequent PET/MRI (120 min). While diagnostic agreement was preserved, quantitative values were influenced by amyloid burden, age, and scan timing. These findings suggest a need for careful consideration when interpreting quantitative metrics across different imaging modalities and time points.

Japanese Journal of Radiology
Kyoto University (JP), Kyoto University Hospital (JP)
Openalex Percentile: Top 46%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.