From Seconds to Seasons: First-in-Human Insights from a Chronic Subscalp EEG System

Objective: Patient self-report is known to be an inaccurate reflection of true seizure frequency in persons with epilepsy. The current study aimed to assess the safety and performance of the Minder system, a bilateral subscalp electroencephalographic (EEG) acquisition system for continuous long-term EEG recording. Methods: This prospective, multicenter first-in-human study enrolled adult patients with focal or generalized epilepsy and at least 2 seizures per month. The primary outcome was adverse events (AEs) in the first 6 months of implantation. Secondary analyses determined whether normal neurophysiological signals, interictal discharges, and seizures seen on scalp video EEG monitoring were identifiable on subscalp recordings, and signals were rated for clarity on subscalp and 2-channel scalp EEG recordings (1 = not recognizable, 5 = clear). Subscalp data were reviewed in relation to events reported in 6-month seizure diaries. Results: Twenty-six subjects were implanted between November 2019 and July 2023. No serious device- or implant procedure-related AEs were reported. The most common device-related AEs were mild or moderate postsurgical pain, headache, or scalp pain/paresthesia (9/26, 35%). All sleep spindles, chewing artifacts, interictal discharges, and electrographic seizures observed on scalp recordings (25 seizures from 8 patients) were identified on subscalp recordings and given higher clarity ratings compared to 2-channel scalp recordings (median seizure clarity rating was 3 for both scalp and subscalp EEG, range = 1-5, P = .0025). Subscalp recordings captured seizures from diverse seizure focus locations, including frontal and mesial temporal seizure foci and hypothalamic hamartoma. Bilateral recording revealed clinically relevant findings not possible with unilateral recordings (6/26 patients, 23%). Findings of potential clinical utility were identified on manual review of 6-month recordings in most patients (23/26, 88%). Significance: This study demonstrates the safety and performance of the Minder bilateral subscalp EEG acquisition system for long-term seizure monitoring in patients with epilepsy. Bilateral hemisphere coverage captured seizures in a diverse patient group and permitted lateralization of events.

Authors

Institutions

Publication Details

Journal
Epiliepsy currents/Epilepsy currents
Published
2025-12-09
DOI
https://doi.org/10.1177/15357597251407040
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From Seconds to Seasons: First-in-Human Insights from a Chronic Subscalp EEG System

Shruti Agashe
Epiliepsy currents/Epilepsy currents
EEG and Brain-Computer Interfaces
article

From Seconds to Seasons: First-in-Human Insights from a Chronic Subscalp EEG System

Shruti Agashe
article en

Abstract

Objective: Patient self-report is known to be an inaccurate reflection of true seizure frequency in persons with epilepsy. The current study aimed to assess the safety and performance of the Minder system, a bilateral subscalp electroencephalographic (EEG) acquisition system for continuous long-term EEG recording. Methods: This prospective, multicenter first-in-human study enrolled adult patients with focal or generalized epilepsy and at least 2 seizures per month. The primary outcome was adverse events (AEs) in the first 6 months of implantation. Secondary analyses determined whether normal neurophysiological signals, interictal discharges, and seizures seen on scalp video EEG monitoring were identifiable on subscalp recordings, and signals were rated for clarity on subscalp and 2-channel scalp EEG recordings (1 = not recognizable, 5 = clear). Subscalp data were reviewed in relation to events reported in 6-month seizure diaries. Results: Twenty-six subjects were implanted between November 2019 and July 2023. No serious device- or implant procedure-related AEs were reported. The most common device-related AEs were mild or moderate postsurgical pain, headache, or scalp pain/paresthesia (9/26, 35%). All sleep spindles, chewing artifacts, interictal discharges, and electrographic seizures observed on scalp recordings (25 seizures from 8 patients) were identified on subscalp recordings and given higher clarity ratings compared to 2-channel scalp recordings (median seizure clarity rating was 3 for both scalp and subscalp EEG, range = 1-5, P = .0025). Subscalp recordings captured seizures from diverse seizure focus locations, including frontal and mesial temporal seizure foci and hypothalamic hamartoma. Bilateral recording revealed clinically relevant findings not possible with unilateral recordings (6/26 patients, 23%). Findings of potential clinical utility were identified on manual review of 6-month recordings in most patients (23/26, 88%). Significance: This study demonstrates the safety and performance of the Minder bilateral subscalp EEG acquisition system for long-term seizure monitoring in patients with epilepsy. Bilateral hemisphere coverage captured seizures in a diverse patient group and permitted lateralization of events.

Epiliepsy currents/Epilepsy currents
Duke University (US)
Openalex Percentile: Top 60%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.