High frame rate ultrasonic flowmeter based on PMUT array with bidirectional acoustic beams

This paper demonstrated the feasibility of utilizing miniaturized piezoelectric micromachined ultrasonic transducer (PMUT) to form a symmetric V-shaped acoustic beam pattern, which enables the ability to synchronously transmit bidirectional ultrasonic signals, and offers a promising technology to address the frame rate limitations in traditional ultrasonic flowmeters based on time-of-flight (ToF). In contrast to the previous two-step flow rate monitoring scheme, where paired ultrasonic transducers are used as transmitter and receiver alternately to obtain the upstream and downstream ultrasound propagation time sequentially, we proposed one-step mid-air flow rate measurement with a remarkable frame rate through the V-shaped bidirectional beam generated by a 3.6 mm × 3.6 mm 5-channel ~250 kHz PZT PMUT phased array. By utilizing the grating lobe produced through optimized array pitch design and sequential control, this 5-channel PMUT array breaks the conventional design limitations typically associated with grating lobes, and generates the V-shaped beam with dual main lobes measured at 27° and 153°, enabling 1000 times of upstream and downstream ToF measurements in 1 s. Furthermore, installation geometry optimization was proposed to enhance the ToF resolution and adaptation to various pipe circumstances, where flow rate measurements in conventional straight pipe and optimized zigzag-shaped pipe with 150 mm sufficient ultrasound propagation length were investigated. The experiment results demonstrated the superior flow rate monitoring performance of our device and system, where large-range (0.5-35 L·min<sup>-1</sup> or 0.045-3.177 m·s<sup>-1</sup>, airflow) and high-resolution (185 ns/(L·min<sup>-1</sup>) or 2032 ns/(m·s<sup>-1</sup>)) flow metering with significant linearity (0.997) was successfully obtained, revealing great potential in advanced flow monitoring application scenarios.

Authors

Institutions

Publication Details

Journal
Microsystems & Nanoengineering
Published
2025-12-10
DOI
https://doi.org/10.1038/s41378-025-01096-x
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High frame rate ultrasonic flowmeter based on PMUT array with bidirectional acoustic beams

Bowen Sheng, Yipeng Lu, Ziyi Liang, Chong Yang et al.
Microsystems & Nanoengineering
Flow Measurement and Analysis
article

High frame rate ultrasonic flowmeter based on PMUT array with bidirectional acoustic beams

Bowen Sheng, Yipeng Lu, Ziyi Liang, Chong Yang, Lei Zhao, Yufeng Gao, Aocheng Bao, Xili Wang
article en

Abstract

This paper demonstrated the feasibility of utilizing miniaturized piezoelectric micromachined ultrasonic transducer (PMUT) to form a symmetric V-shaped acoustic beam pattern, which enables the ability to synchronously transmit bidirectional ultrasonic signals, and offers a promising technology to address the frame rate limitations in traditional ultrasonic flowmeters based on time-of-flight (ToF). In contrast to the previous two-step flow rate monitoring scheme, where paired ultrasonic transducers are used as transmitter and receiver alternately to obtain the upstream and downstream ultrasound propagation time sequentially, we proposed one-step mid-air flow rate measurement with a remarkable frame rate through the V-shaped bidirectional beam generated by a 3.6 mm × 3.6 mm 5-channel ~250 kHz PZT PMUT phased array. By utilizing the grating lobe produced through optimized array pitch design and sequential control, this 5-channel PMUT array breaks the conventional design limitations typically associated with grating lobes, and generates the V-shaped beam with dual main lobes measured at 27° and 153°, enabling 1000 times of upstream and downstream ToF measurements in 1 s. Furthermore, installation geometry optimization was proposed to enhance the ToF resolution and adaptation to various pipe circumstances, where flow rate measurements in conventional straight pipe and optimized zigzag-shaped pipe with 150 mm sufficient ultrasound propagation length were investigated. The experiment results demonstrated the superior flow rate monitoring performance of our device and system, where large-range (0.5-35 L·min<sup>-1</sup> or 0.045-3.177 m·s<sup>-1</sup>, airflow) and high-resolution (185 ns/(L·min<sup>-1</sup>) or 2032 ns/(m·s<sup>-1</sup>)) flow metering with significant linearity (0.997) was successfully obtained, revealing great potential in advanced flow monitoring application scenarios.

Microsystems & NanoengineeringVol. 11(1)
Peking University (CN)
National Natural Science Foundation of China, Peking University
Openalex Percentile: Top 56%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.