Band-limited implicit neural representations for diffusion-weighted imaging denoising

<i>Purpose.</i>Diffusion-weighted imaging (DWI) has significant value in disease diagnosis and treatment response monitoring, but its inherent low signal-to-noise ratio (SNR) severely affects image quality and quantification accuracy. Existing denoising techniques often blur important tissue boundary information when suppressing noise.<i>Methods.</i>This study proposes a band-limited implicit neural representation (BL-INR) framework for DWI denoising. The method introduces BL positional encoding based on the frequency response characteristics of the sinc function to restrict INR models from learning high-frequency noise while maintaining strong signal representation capabilities. Furthermore, multi-<i>b</i>-value DWI and structural MRI from the same patient are integrated as anatomical priors, exploiting the correlation between true signals and the statistical independence of noise to achieve effective denoising.<i>Main Results.</i>In clinical DWI data evaluation across four anatomical regions (brain, head and neck, abdomen, and pelvis), BL-INR's visualization results were superior to existing methods. Under extremely low SNR conditions (SNR = 1) in simulated noise experiments, BL-INR achieved a peak SNR of 35.44 and structural similarity index of 0.933, significantly outperforming other methods. Phantom denoising results showed that BL-INR achieved an average apparent diffusion coefficient value error of only4.57×10-5 mm<sup>2</sup> s<sup>-1</sup>, the smallest among all methods.<i>Significance.</i>BL-INR provides a novel approach for DWI denoising by limiting the frequency of INR input positional encoding. Its self-supervised learning characteristics require no paired training data and allow convenient clinical application. The method enables the derivation of accurate diffusion parameters, providing a reliable foundation for DWI-based quantitative analysis with significant clinical application value.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-12-09
DOI
https://doi.org/10.1088/1361-6560/ae2a9e
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Band-limited implicit neural representations for diffusion-weighted imaging denoising

Jie Deng, Yen‐Peng Liao, Yan Dai, You Zhang et al.
Physics in Medicine and Biology
Advanced Neuroimaging Techniques and Applications
article

Band-limited implicit neural representations for diffusion-weighted imaging denoising

Jie Deng, Yen‐Peng Liao, Yan Dai, You Zhang, Yunxiang Li
article en

Abstract

<i>Purpose.</i>Diffusion-weighted imaging (DWI) has significant value in disease diagnosis and treatment response monitoring, but its inherent low signal-to-noise ratio (SNR) severely affects image quality and quantification accuracy. Existing denoising techniques often blur important tissue boundary information when suppressing noise.<i>Methods.</i>This study proposes a band-limited implicit neural representation (BL-INR) framework for DWI denoising. The method introduces BL positional encoding based on the frequency response characteristics of the sinc function to restrict INR models from learning high-frequency noise while maintaining strong signal representation capabilities. Furthermore, multi-<i>b</i>-value DWI and structural MRI from the same patient are integrated as anatomical priors, exploiting the correlation between true signals and the statistical independence of noise to achieve effective denoising.<i>Main Results.</i>In clinical DWI data evaluation across four anatomical regions (brain, head and neck, abdomen, and pelvis), BL-INR's visualization results were superior to existing methods. Under extremely low SNR conditions (SNR = 1) in simulated noise experiments, BL-INR achieved a peak SNR of 35.44 and structural similarity index of 0.933, significantly outperforming other methods. Phantom denoising results showed that BL-INR achieved an average apparent diffusion coefficient value error of only4.57×10-5 mm<sup>2</sup> s<sup>-1</sup>, the smallest among all methods.<i>Significance.</i>BL-INR provides a novel approach for DWI denoising by limiting the frequency of INR input positional encoding. Its self-supervised learning characteristics require no paired training data and allow convenient clinical application. The method enables the derivation of accurate diffusion parameters, providing a reliable foundation for DWI-based quantitative analysis with significant clinical application value.

Physics in Medicine and BiologyVol. 71(1)
Southwestern Medical Center (US), Southwestern Medical Center (US), The University of Texas Southwestern Medical Center (US)
Openalex Percentile: Top 46%
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.