An electrical pulse artifact signal for estimating arterial blood pressure: a proof-of-concept study

<i>Objective.</i>Hypertension is a leading cause of mortality worldwide, for which myriad treatment options are available. It is widely considered that continuous measurement of arterial blood pressure (BP) could improve the treatment of hypertension; however, chronically monitoring patient BP remains a significant challenge. In this study, we investigated a novel approach that uses an implantable electrode to generate an artifact signal for predicting arterial BP.<i>Approach.</i>In isoflurane anesthetized rats (<i>n</i>= 10, male), the right common carotid artery was instrumented with a multi-contact cuff electrode to acquire the artifact signal-termed the electro-vascular-gram (EVG) and the contralateral common carotid artery was catheterized to measure intra-arterial BP. The EVG signals were processed (e.g. extract Catch22 features) and applied to linear regression, random forest (RF) regressor, and convolutional neural network models to predict systolic and diastolic BP.<i>Main results.</i>Among the various models tested with the EVG data, the RF model + Catch22 features method achieved the highest performance, yielding predicted BP values (error < 5 mmHg) in 82.6%-100% and 84.1%-99.9% of the testing set for systolic and diastolic, respectively. A 5-fold cross-validation demonstrated similar performance by predicting BP values (error < 5 mmHg) in 91.5 ± 0.1% and 92.4 ± 0.1% of testing data for systolic and diastolic, respectively.<i>Significance.</i>This proof-of-concept study supports the feasibility of using an implantable electrode and machine learning models for potentially measuring arterial BP in continuous fashion. Further system development is warranted prior to clinical translation.

Authors

Institutions

Publication Details

Journal
Physiological Measurement
Published
2025-12-09
DOI
https://doi.org/10.1088/1361-6579/ae2aa7
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An electrical pulse artifact signal for estimating arterial blood pressure: a proof-of-concept study

Ryan G. L. Koh, Paul B. Yoo, Ali Howidi, Niveetha Wijendran et al.
Physiological Measurement
Non-Invasive Vital Sign Monitoring
article

An electrical pulse artifact signal for estimating arterial blood pressure: a proof-of-concept study

Ryan G. L. Koh, Paul B. Yoo, Ali Howidi, Niveetha Wijendran, Koosha Omidian, Krish Chhajer
article en

Abstract

<i>Objective.</i>Hypertension is a leading cause of mortality worldwide, for which myriad treatment options are available. It is widely considered that continuous measurement of arterial blood pressure (BP) could improve the treatment of hypertension; however, chronically monitoring patient BP remains a significant challenge. In this study, we investigated a novel approach that uses an implantable electrode to generate an artifact signal for predicting arterial BP.<i>Approach.</i>In isoflurane anesthetized rats (<i>n</i>= 10, male), the right common carotid artery was instrumented with a multi-contact cuff electrode to acquire the artifact signal-termed the electro-vascular-gram (EVG) and the contralateral common carotid artery was catheterized to measure intra-arterial BP. The EVG signals were processed (e.g. extract Catch22 features) and applied to linear regression, random forest (RF) regressor, and convolutional neural network models to predict systolic and diastolic BP.<i>Main results.</i>Among the various models tested with the EVG data, the RF model + Catch22 features method achieved the highest performance, yielding predicted BP values (error < 5 mmHg) in 82.6%-100% and 84.1%-99.9% of the testing set for systolic and diastolic, respectively. A 5-fold cross-validation demonstrated similar performance by predicting BP values (error < 5 mmHg) in 91.5 ± 0.1% and 92.4 ± 0.1% of testing data for systolic and diastolic, respectively.<i>Significance.</i>This proof-of-concept study supports the feasibility of using an implantable electrode and machine learning models for potentially measuring arterial BP in continuous fashion. Further system development is warranted prior to clinical translation.

Physiological MeasurementVol. 46(12)
University Health Network (CA), University of Toronto (CA), Toronto Rehabilitation Institute (CA), Rogers (United States) (US)
Openalex Percentile: Top 61%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.