Evaluation and comparison of PENHAN and FLUKA Monte Carlo codes for small-scale dosimetry in targeted radionuclide therapy with alpha emitters

<i>Objective.</i>This study aims to comprehensively compare the PENHAN and FLUKA Monte Carlo codes for low-energy alpha particle transport and small-scale dosimetry using alpha-emitting radionuclides, and to assess their suitability for such applications.<i>Approach.</i>Two studies were performed through Monte Carlo simulations. First, monoenergetic alpha particles (3-10 MeV) were distributed in a micrometric water sphere and the dose deposition within it was calculated. Second, a simplified spherical cell model with uniformly distributed alpha-emitting radionuclides was used to compute<i>S</i>-values. PENHAN and FLUKA results were compared, and potential sources of discrepancy between them were analyzed. In addition, both codes were benchmarked against MIRDcell, an analytical tool widely used for dosimetric calculations in Targeted radionuclide therapy.<i>Main results.</i>In the monoenergetic study, the primary source of discrepancy between PENHAN and FLUKA was the stopping powers used for alpha particles. When the same stopping powers were employed, both codes yielded statistically compatible results, except at 3.0 and 3.5 MeV, where FLUKA showed an anomalous behavior. In the cell model, variations were below 3% but not negligible even when using identical stopping powers, suggesting an additional source of discrepancy: differences in the radionuclide emission spectra, particularly in the electron component. In both studies, PENHAN and FLUKA results were overall in good agreement with those from MIRDcell.<i>Significance.</i>This study demonstrates, for the first time, the suitability of PENHAN for low-energy alpha transport and small-scale dosimetry with alpha emitters, provided that accurate stopping powers are employed. It also supports the reliability of FLUKA in these scenarios and shows that both codes yield compatible results when using consistent stopping power datasets and radionuclide emission spectra. This work further highlights the importance of validating Monte Carlo codes in medical physics to ensure the reliability and reproducibility of their results.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-12-09
DOI
https://doi.org/10.1088/1361-6560/ae2aa6
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation and comparison of PENHAN and FLUKA Monte Carlo codes for small-scale dosimetry in targeted radionuclide therapy with alpha emitters

M. Anguiano, Lidia Palenciano-Castro
Physics in Medicine and Biology
Radiopharmaceutical Chemistry and Applications
article

Evaluation and comparison of PENHAN and FLUKA Monte Carlo codes for small-scale dosimetry in targeted radionuclide therapy with alpha emitters

M. Anguiano, Lidia Palenciano-Castro
article en

Abstract

<i>Objective.</i>This study aims to comprehensively compare the PENHAN and FLUKA Monte Carlo codes for low-energy alpha particle transport and small-scale dosimetry using alpha-emitting radionuclides, and to assess their suitability for such applications.<i>Approach.</i>Two studies were performed through Monte Carlo simulations. First, monoenergetic alpha particles (3-10 MeV) were distributed in a micrometric water sphere and the dose deposition within it was calculated. Second, a simplified spherical cell model with uniformly distributed alpha-emitting radionuclides was used to compute<i>S</i>-values. PENHAN and FLUKA results were compared, and potential sources of discrepancy between them were analyzed. In addition, both codes were benchmarked against MIRDcell, an analytical tool widely used for dosimetric calculations in Targeted radionuclide therapy.<i>Main results.</i>In the monoenergetic study, the primary source of discrepancy between PENHAN and FLUKA was the stopping powers used for alpha particles. When the same stopping powers were employed, both codes yielded statistically compatible results, except at 3.0 and 3.5 MeV, where FLUKA showed an anomalous behavior. In the cell model, variations were below 3% but not negligible even when using identical stopping powers, suggesting an additional source of discrepancy: differences in the radionuclide emission spectra, particularly in the electron component. In both studies, PENHAN and FLUKA results were overall in good agreement with those from MIRDcell.<i>Significance.</i>This study demonstrates, for the first time, the suitability of PENHAN for low-energy alpha transport and small-scale dosimetry with alpha emitters, provided that accurate stopping powers are employed. It also supports the reliability of FLUKA in these scenarios and shows that both codes yield compatible results when using consistent stopping power datasets and radionuclide emission spectra. This work further highlights the importance of validating Monte Carlo codes in medical physics to ensure the reliability and reproducibility of their results.

Physics in Medicine and BiologyVol. 70(24)
Universidad de Granada (ES), Complejo Hospitalario Universitario de Granada (ES)
Ministerio de Ciencia, Innovación y Universidades, European Commission, European Regional Development Fund, Agencia Estatal de Investigación
Openalex Percentile: Top 46%
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.