Effect of Tesla valve geometry on unsteady flow behavior and pressure drop

Computational fluid dynamics (CFD) simulations are carried out to examine the effect of geometricparameters of Tesla valve on flow patterns, pressure drop and flow diodicity. In forward flow, the flow is relatively smooth with less flow resistance. The low velocity regions are present at the entrance to the curved section and at thejunction of the curved section and the exit channel, where flow separation takes place. In reverse flow, the flow is quite irregular, and major recirculation zones are observed in the bottom branch, in addition to the top-curved and exit sections. The simulations with small time steps show that the flow is steady when the flow takes place in the forwarddirection. The flow is mostly transient; however, when the fluid flows in the reverse direction, particularly at higher Reynolds numbers. The effect of geometric parameters such as the angles subtended by the curved section (with thehorizontal) shows that optimal values of these angles exist. For a certain range of angles, diodicity is greater than 2.The effect of multi-staging of the Tesla valve is studied, and it is found that the flow unsteadiness and overall diodicity increase with the number of stages.

Authors

Institutions

Publication Details

Journal
Memoria Investigaciones en Ingeniería
Published
2025-12-09
DOI
https://doi.org/10.36561/ing.29.5
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Tesla valve geometry on unsteady flow behavior and pressure drop

M. Shakaib, Muhammad Ehtesham ul Haque, S. M. F. Hasani
Memoria Investigaciones en Ingeniería
Flow Measurement and Analysis
article

Effect of Tesla valve geometry on unsteady flow behavior and pressure drop

M. Shakaib, Muhammad Ehtesham ul Haque, S. M. F. Hasani
article en

Abstract

Computational fluid dynamics (CFD) simulations are carried out to examine the effect of geometricparameters of Tesla valve on flow patterns, pressure drop and flow diodicity. In forward flow, the flow is relatively smooth with less flow resistance. The low velocity regions are present at the entrance to the curved section and at thejunction of the curved section and the exit channel, where flow separation takes place. In reverse flow, the flow is quite irregular, and major recirculation zones are observed in the bottom branch, in addition to the top-curved and exit sections. The simulations with small time steps show that the flow is steady when the flow takes place in the forwarddirection. The flow is mostly transient; however, when the fluid flows in the reverse direction, particularly at higher Reynolds numbers. The effect of geometric parameters such as the angles subtended by the curved section (with thehorizontal) shows that optimal values of these angles exist. For a certain range of angles, diodicity is greater than 2.The effect of multi-staging of the Tesla valve is studied, and it is found that the flow unsteadiness and overall diodicity increase with the number of stages.

Memoria Investigaciones en Ingeniería(29)
NED University of Engineering and Technology (PK), Imam Mohammad ibn Saud Islamic University (SA), Islamic University (BD)
University of Engineering and Technology, Lahore, NED University of Engineering and Technology
Openalex Percentile: Top 56%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.