Imaging quality optimization of cross-strip anode single-photon detectors based on the three Gaussian algorithms

Cross-strip (XS) anode single-photon detectors are highly valuable for detecting distant dim targets owing to their excellent sensitivity and spatial resolution. However, traditional reconstruction algorithms (G3S and MCOG) suffer from severe imaging distortions. To address this issue, we propose a modified Gaussian 3 strip (MG3S) algorithm, developed through a combination of Monte Carlo simulations and practical experiments. Experimental results show that MG3S improves the imaging resolution from 55.7 µm (G3S) and 49.6 µm (MCOG) to 44.2 µm, increases the structural similarity index (SSIM) with the reference image from 0.0594 (G3S) and 0.0724 (MCOG) to 0.1412, and raises the peak signal-to-noise ratio (PSNR) from 7.857 dB (G3S) and 8.025 dB (MCOG) to 9.893 dB. These improvements result from the effective suppression of fixed-pattern noise and rejection of abnormal data. The robustness and computational complexity of the three algorithms are also compared. This work provides new insights, to our knowledge, into high-precision image reconstruction for XS anode single-photon detectors and enables accurate detection and imaging of distant dim space targets.

Authors

Publication Details

Journal
Applied Optics
Published
2025-12-09
DOI
https://doi.org/10.1364/ao.579051
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Imaging quality optimization of cross-strip anode single-photon detectors based on the three Gaussian algorithms

Junkai Peng, Bin Wang, Qiliang Ni
Applied Optics
Advanced X-ray and CT Imaging
article

Imaging quality optimization of cross-strip anode single-photon detectors based on the three Gaussian algorithms

Junkai Peng, Bin Wang, Qiliang Ni
article en

Abstract

Cross-strip (XS) anode single-photon detectors are highly valuable for detecting distant dim targets owing to their excellent sensitivity and spatial resolution. However, traditional reconstruction algorithms (G3S and MCOG) suffer from severe imaging distortions. To address this issue, we propose a modified Gaussian 3 strip (MG3S) algorithm, developed through a combination of Monte Carlo simulations and practical experiments. Experimental results show that MG3S improves the imaging resolution from 55.7 µm (G3S) and 49.6 µm (MCOG) to 44.2 µm, increases the structural similarity index (SSIM) with the reference image from 0.0594 (G3S) and 0.0724 (MCOG) to 0.1412, and raises the peak signal-to-noise ratio (PSNR) from 7.857 dB (G3S) and 8.025 dB (MCOG) to 9.893 dB. These improvements result from the effective suppression of fixed-pattern noise and rejection of abnormal data. The robustness and computational complexity of the three algorithms are also compared. This work provides new insights, to our knowledge, into high-precision image reconstruction for XS anode single-photon detectors and enables accurate detection and imaging of distant dim space targets.

Applied OpticsVol. 65(2)
Openalex Percentile: Top 61%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.