A high-performance DC–AC signal separated photodetector for photothermal heterodyne imaging (PHI)

A direct current-alternating current (DC-AC) separated photodiode detector has been developed and optimized for the signal characteristics of photothermal heterodyne imaging (PHI). The detector features a large photosensitive area (diameter = 5 mm), a flat frequency response, and a single-photodiode design. The gains of the DC and AC signal channels can be independently configured, for example, a gain of 103 for the DC signal and 105 for the AC signal. The cutoff frequency is set to 1.6 kHz, and the -3 dB bandwidth of transimpedance amplifier reaches about 5.8 MHz. This detector is easy to operate, highly resistant to external noise, and meets the imaging requirements of PHI experiments.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-12-01
DOI
https://doi.org/10.1063/5.0293559
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A high-performance DC–AC signal separated photodetector for photothermal heterodyne imaging (PHI)

Dou-Dou Ren, Zhi‐Cong Zeng, Tang-Xiu Li, W. W. Zhang et al.
Review of Scientific Instruments
Photoacoustic and Ultrasonic Imaging
article

A high-performance DC–AC signal separated photodetector for photothermal heterodyne imaging (PHI)

Dou-Dou Ren, Zhi‐Cong Zeng, Tang-Xiu Li, W. W. Zhang, Ting Pan, Haixia Zhang, Yuewen Zhang, Mei-Ling Sa, Xiu-Jia Yang, Yan‐Ping Shi
article en

Abstract

A direct current-alternating current (DC-AC) separated photodiode detector has been developed and optimized for the signal characteristics of photothermal heterodyne imaging (PHI). The detector features a large photosensitive area (diameter = 5 mm), a flat frequency response, and a single-photodiode design. The gains of the DC and AC signal channels can be independently configured, for example, a gain of 103 for the DC signal and 105 for the AC signal. The cutoff frequency is set to 1.6 kHz, and the -3 dB bandwidth of transimpedance amplifier reaches about 5.8 MHz. This detector is easy to operate, highly resistant to external noise, and meets the imaging requirements of PHI experiments.

Review of Scientific InstrumentsVol. 96(12)
Lanzhou Institute of Chemical Physics (CN), University of Chinese Academy of Sciences (CN), Lanzhou University (CN)
Openalex Percentile: Top 62%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A high-performance DC–AC signal separated photodetector for photothermal heterodyne imaging (PHI) — Dou-Dou Ren, Zhi‐Cong Zeng, et al. · Review of Scientific Instruments (2025) | TGRS Research Map | TGRS