Spectral-Based Temperature Sensing in Cr:LiCAF Crystals Using Fluorescence Peak Shift Calibration
In this study, we present a non-invasive and contactless method for estimating the internal temperature of Cr:LiCAF laser crystals using temperature-dependent shifts in fluorescence emission peaks. A high-resolution calibration dataset was created with 181 spectral points from 10 to 100 °C. Linear regression yielded a temperature estimation model with an R2 of 0.73, which was validated under both lasing and non-lasing conditions. To further evaluate the reliability of this optical thermometry method, thermal imaging data from a FLIR E75 infrared camera were incorporated. Surface temperatures measured at various diode current levels closely matched the internal temperature predictions based on fluorescence shifts (MAE = 0.775 °C, R2 = 0.993), confirming the robustness of the method. This dual-approach validation enhances confidence in using fluorescence-based diagnostics for real-time thermal monitoring in laser systems. The combined use of spectrometer-based and thermal camera measurements suggests potential for hybrid diagnostics in laser research and development, offering improved thermal feedback for optimizing high-power laser performance.
Authors
- Yusuf Öztürk (ORCID: https://orcid.org/0000-0003-2762-5265)
Institutions
- Antalya Bilim University (TR)
Publication Details
- Journal
- Crystals
- Published
- 2025-12-09
- DOI
- https://doi.org/10.3390/cryst15121047
- Primary Topic
- Solid State Laser Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Türkiye Bilimsel ve Teknolojik Araştırma Kurumu