Spectral-Based Temperature Sensing in Cr:LiCAF Crystals Using Fluorescence Peak Shift Calibration

In this study, we present a non-invasive and contactless method for estimating the internal temperature of Cr:LiCAF laser crystals using temperature-dependent shifts in fluorescence emission peaks. A high-resolution calibration dataset was created with 181 spectral points from 10 to 100 °C. Linear regression yielded a temperature estimation model with an R2 of 0.73, which was validated under both lasing and non-lasing conditions. To further evaluate the reliability of this optical thermometry method, thermal imaging data from a FLIR E75 infrared camera were incorporated. Surface temperatures measured at various diode current levels closely matched the internal temperature predictions based on fluorescence shifts (MAE = 0.775 °C, R2 = 0.993), confirming the robustness of the method. This dual-approach validation enhances confidence in using fluorescence-based diagnostics for real-time thermal monitoring in laser systems. The combined use of spectrometer-based and thermal camera measurements suggests potential for hybrid diagnostics in laser research and development, offering improved thermal feedback for optimizing high-power laser performance.

Authors

Institutions

Publication Details

Journal
Crystals
Published
2025-12-09
DOI
https://doi.org/10.3390/cryst15121047
Primary Topic
Solid State Laser Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spectral-Based Temperature Sensing in Cr:LiCAF Crystals Using Fluorescence Peak Shift Calibration

Yusuf Öztürk
Crystals
Solid State Laser Technologies
article

Spectral-Based Temperature Sensing in Cr:LiCAF Crystals Using Fluorescence Peak Shift Calibration

Yusuf Öztürk
article en

Abstract

In this study, we present a non-invasive and contactless method for estimating the internal temperature of Cr:LiCAF laser crystals using temperature-dependent shifts in fluorescence emission peaks. A high-resolution calibration dataset was created with 181 spectral points from 10 to 100 °C. Linear regression yielded a temperature estimation model with an R2 of 0.73, which was validated under both lasing and non-lasing conditions. To further evaluate the reliability of this optical thermometry method, thermal imaging data from a FLIR E75 infrared camera were incorporated. Surface temperatures measured at various diode current levels closely matched the internal temperature predictions based on fluorescence shifts (MAE = 0.775 °C, R2 = 0.993), confirming the robustness of the method. This dual-approach validation enhances confidence in using fluorescence-based diagnostics for real-time thermal monitoring in laser systems. The combined use of spectrometer-based and thermal camera measurements suggests potential for hybrid diagnostics in laser research and development, offering improved thermal feedback for optimizing high-power laser performance.

CrystalsVol. 15(12)
Antalya Bilim University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Openalex Percentile: Top 60%
Solid State Laser Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Spectral-Based Temperature Sensing in Cr:LiCAF Crystals Using Fluorescence Peak Shift Calibration — Yusuf Öztürk · Crystals (2025) | TGRS Research Map | TGRS