Diaphragmatic ultrasound and thoracic fluid content for prediction of non-invasive ventilation failure in neonates: a randomized controlled trial
• DTF and DE measured by ultrasound show a strong correlation with TFC obtained by EC in predicting NIV failure. Additionally, DTF and DE have higher predictive accuracy than TFC in identifying preterm neonates at risk of NIV failure. • Early assessment of DTF and DE may serve as a valuable bedside tool for monitoring lung function during early application of NIV in preterm infants.
Authors
- Heba Elmahdy (ORCID: https://orcid.org/0000-0003-4209-5100)
- Mohamed Adel Eltomey
- M. Nassar (ORCID: https://orcid.org/0000-0003-1893-5165)
- Essam A. El-Gendy
- Hamed Mohamed Elsharkawy
- Lamiaa Khaled Zidan (ORCID: https://orcid.org/0009-0003-4880-020X)
Institutions
- Tanta University (EG)
- Tanta University Hospital (EG)
Publication Details
- Journal
- European Journal of Pediatrics
- Published
- 2025-12-09
- DOI
- https://doi.org/10.1007/s00431-025-06605-8
- Primary Topic
- Neonatal Respiratory Health Research
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Science and Technology Development Fund